Service and Repair Manual
October 2016
Platform Components
36
ZX-135/70
Part No. 1268558
2-4
Platform Level Sensor
The platform level sensor is mounted to the side of
the platform rotator. The platform level sensor is
monitored by the control system to maintain a level
platform through boom range of motion. If a
platform level sensor is replaced, it must be
calibrated prior to machine operation.
How to Calibrate the Platform
Level Sensor
Note: Perform this procedure with the machine on a
firm, level surface.
Note: Perform this procedure with the boom in the
stowed position.
Note: Use the following chart to identify the
description of each LCD screen control button used
in this procedure.
Plus
Minus
Previous
Enter
1
Secure a digital level to one of the side railings
of the platform.
2
Start the machine and level the platform to
gravity. Turn the machine off.
3
Open the ground control box.
4
Locate the calibration toggle switch at the top
of the ground control box. Activate calibration
mode by moving the toggle switch in the left
direction.
5
Temporarily install a control box door retaining
fastener between the door and the box to
prevent the control box door from moving the
toggle switch while calibrating the machine.
6
Insert the key into the bypass/recovery key
switch and turn it to the bypass position.
Note: The angle sensor calibration values will not
be saved correctly unless the key switch is in the
bypass position and the calibration toggle switch is
activated.
7
Press and hold the
enter
button on the ground
control panel while turning the key switch to
ground controls. Hold the
enter
button for
approximately 5 seconds.
8
Enter sensor calibration mode by pressing the
buttons at the ground controls in the following
sequence:
(plus)(enter)(enter)(plus)
.
9
Press the
enter
or
previous
button on the
LCD screen until SET
PLATFORM
LEVEL
SENSOR
TO
GRAVITY is displayed.
10 Press the
plus
button to select YES, then
press the
enter
button to accept.
11 Press the
enter
or
previous
button on the
LCD screen until EXIT is displayed.
12 Press the
plus
button to select YES, then
press the
enter
button to accept.
13 Remove the fastener that was temporarily
installed. Close the control box door and install
the door retaining fasteners.
Note: When the control box door is closed, the
calibration toggle switch is automatically activated
to exit out of calibration mode.
Summary of Contents for Genie Z13505-101
Page 12: ......
Page 121: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 109 ...
Page 123: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 111 ...
Page 129: ...October 2016 Service and Repair Manual Part No 1268558 ZX 135 70 117 ...
Page 135: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 123 ...
Page 137: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 125 ...
Page 141: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 129 ...
Page 143: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 131 ...
Page 233: ...October 2016 Service and Repair Manual 221 Perkins 1104D 44T Engine Electrical Schematic ...
Page 235: ...October 2016 Service and Repair Manual 223 Perkins 854F 34T Engine Electrical Schematic ...
Page 238: ...Service and Repair Manual October 2016 226 Perkins 854F 34T Engine Harness ...
Page 239: ...October 2016 Service and Repair Manual 227 Deutz TD2 9 Engine Electrical Schematic ...
Page 242: ...Service and Repair Manual October 2016 230 Deutz TD2 9 Engine Harness ...
Page 243: ...October 2016 Service and Repair Manual 231 Hydraulic Generator Welder Option ...
Page 246: ...Service and Repair Manual October 2016 234 Generator Wiring Schematic ...
Page 247: ...October 2016 Service and Repair Manual 235 Hydraulic Schematic to SN ZX13516H 2804 ...
Page 250: ...Service and Repair Manual October 2016 238 Hydraulic Schematic from SN ZX13516H 2805 ...
Page 253: ......