Service and Repair Manual
October 2016
Manifolds
134
ZX-135/70
Part No. 1268558
8-13
Valve Coils
How to Test a Coil
A properly functioning coil provides an
electromotive force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil that provides this force field.
Since coil resistance is sensitive to temperature,
resistance values outside specification can produce
erratic operation. When coil resistance decreases
below specification, amperage increases. As
resistance rises above specification, voltage
increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
1
Tag and disconnect the wiring from the coil to
be tested.
2
Test the coil resistance.
Result: The resistance should be within
specification, plus or minus 30%.
Result: If the resistance is not within
specification, plus or minus 30%, replace the
coil.
Valve Coil Resistance
Specification
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / 10°C
that your air temperature increases or decreases
from 68°F / 20°C.
Valve Coil Resistance Specification
3 position 4 way solenoid valve
(schematic item A, B, C, D, W)
7.2Ω
2 position 3 way solenoid valve
(schematic items D, E, F, G, I, Z )
5.6Ω
2 position 3 way solenoid valve
(schematic items P,Q )
7.2Ω
2 position 3 way solenoid valve
(schematic items AE )
8.8Ω
3 position 4 way proportional solenoid valve
(schematic items Y and AF)
8.8Ω
2 position 2 way solenoid valve
(schematic item A)
3.5 to
5.5Ω
Summary of Contents for Genie Z13505-101
Page 12: ......
Page 121: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 109 ...
Page 123: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 111 ...
Page 129: ...October 2016 Service and Repair Manual Part No 1268558 ZX 135 70 117 ...
Page 135: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 123 ...
Page 137: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 125 ...
Page 141: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 129 ...
Page 143: ...October 2016 Service and Repair Manual Manifolds Part No 1268558 ZX 135 70 131 ...
Page 233: ...October 2016 Service and Repair Manual 221 Perkins 1104D 44T Engine Electrical Schematic ...
Page 235: ...October 2016 Service and Repair Manual 223 Perkins 854F 34T Engine Electrical Schematic ...
Page 238: ...Service and Repair Manual October 2016 226 Perkins 854F 34T Engine Harness ...
Page 239: ...October 2016 Service and Repair Manual 227 Deutz TD2 9 Engine Electrical Schematic ...
Page 242: ...Service and Repair Manual October 2016 230 Deutz TD2 9 Engine Harness ...
Page 243: ...October 2016 Service and Repair Manual 231 Hydraulic Generator Welder Option ...
Page 246: ...Service and Repair Manual October 2016 234 Generator Wiring Schematic ...
Page 247: ...October 2016 Service and Repair Manual 235 Hydraulic Schematic to SN ZX13516H 2804 ...
Page 250: ...Service and Repair Manual October 2016 238 Hydraulic Schematic from SN ZX13516H 2805 ...
Page 253: ......