Sec-4.8
Section 4: Programming
Adding a Transmitter
1. If operator is in RUN mode, press CAL/RUN to enter CALIBRATION MODE.
2. Press SCROLL (up or down) until display reads LEARN NEW XMTR? FIG. 1.
•
This question along with the instruction HIT SET FOR YES will continuously pan across the display
window. (Pressing SCROLL or CAL/RUN will cancel the operation).
3. Press SET/CLEAR.
•
Display will read PUSH XMTR BUTTON TWO TIMES TO LEARN XMTR.
4. Press transmitter button two times.
•
The display will read XMTR ___LEARNED. Where it assigns a random number to the transmitter. That
transmitter is entered and ready to operate the door. (Label/mark the transmitter).
5. Press SCROLL (up or down) to move on to another menu item, or CAL/RUN to exit CALIBRATION mode.
Removing Individual Transmitter
6. If operator is in RUN mode, press CAL/RUN to enter CALIBRATION MODE.
7. Press SCROLL (up or down) until display reads CLR ONE XMTR? FIG. 2.
8. Press SET/CLEAR.
•
A menu displaying the available transmitter numbers will appear.
•
Press SCROLL (up or down) to cycle through the menu to the number of the transmitter to be removed.
(Pressing CAL/RUN will cancel the operation).
9. Press SET/CLEAR
•
The transmitter is removed.
10. Press SCROLL (up or down) to move on to another menu item, or CAL/RUN to exit CALIBRATION
mode.
Removing All Transmitters
1. If operator is in RUN mode, press CAL/RUN to enter
CALIBRATION MODE.
2. Press SCROLL (up or down) until display reads CLR EVERY XMTR
FIG. 3.
3. Press the SET/CLEAR key.
•
The display will read <YES> NO.
4. Press SET/CLEAR key.
•
All transmitters are removed.
5. Press SCROLL (up or down) to move on to another menu item,
or CAL/RUN to exit CALIBRATION mode.
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
LEARN NEW XMTR?
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
CLR ONE XMTR
FIG. 1
FIG. 2
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
CLR EVERY XMTR
FIG. 3