Sec-3.3
Line Voltage Wiring:
Section 3: Wiring
-
HIGH VOLTAGE
INPUT PLUG
LINE INPUT
TERMINALS
LINE
GROUND
ROUTE LINE VOLTAGE
WIRING IN SHADED
AREA AS SHOWN
L1
N
GND
LINE IN
120V
LINE
(HOT)
NEUTRAL
HIGH VOLTAGE
INPUT PLUG
POWER CONNECTIONS
DO NOT DRILL ELECTRIC BOX
Remove plugs to install wiring
1. Remove line voltage input plug and install proper fittings and 1/2” conduit.
2. Route proper line voltage wires into operator.
3. Locate line input terminals on circuit board. Using correct connectors, attach wires to line inputs, and
ground terminal.
•
Keep low voltage and line voltage wires separate.
•
Route all line voltage wires as shown.
•
Plug all unused conduit holes.