REMOTE
VIDEO OUT
DC
VIDEO
POWER
SET
F.G
D/N
IN G
M/D
OUT
UTP
OUT
RS485
AC90~230V~
50Hz/60Hz 4.5W
Dual Power Type
(AC 24V/DC 12V, AC 24V Class2)
DC Power Type (DC 12V, 500mA)
AC90~240V-50Hz/60Hz 4.5W
18
PIXIM True Day/Night Bodied Camera
19
PIXIM True Day/Night Bodied Camera
Since power specifications differ depending on the model, make sure
to check your model name and specifications before connecting power.
You can connect power as shown in the following figure.
• Check the standard power requirement before connecting to power.
When the resistance value of copper wire is at [20°C(68°F)]
• As shown in the table above, voltage decreases as the wire gets longer.
Therefore use of an excessively long adaptor output line for connection
to the camera may affect the performance of the camera.
※
Standard voltage for camera operation : DC 12V±10%, AC 24V±10%
※
There may be some deviation in voltage drop depending on the type
of wire and the manufacturer.
Connecting Power
For AC / DC power
#24(0.22mm
2
)
Copper wire size(AWG)
#22(0.33mm
2
) #20(0.52mm
2
) #18(0.83mm
2
)
Resistance value( /m)
0.018
0.030
0.050
0.078
Voltage drop(V/m)
0.006
0.011
0.018
0.028
When using UTP Cable
• Connect UTP (Unshielded Twisted Pair) directly to the UTP output of
this camera. The camera contains a passive UTP Balun.
• A UTP receiver, either passive or active, is needed at the Monitor or
DVR to connect your UTP cable.
• When connecting the UTP cable make sure the video signal is transmitted
over one pair of wires and the polarity is correct.
• Only use Category 5e/6 24 awg cable.
Control via RS-485 Interface
RS-485 Control Port
485 Control Board Connection Port
485+
(+) CONNECTION TERMINAL (TRX+)
(-) CONNECTION TERMINAL (TRX-)
485-
The camera can be controlled by using an external controller equipped
with RS-485 communications.
• To control using a DVR or keyboard controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of
the 485 control board in the DVR or controller.
* RS-485 communication default initial values
• To control the camera use Pelco-D protocol.
- Set Preset 95 : Enters into OSD menu.
- Iris Open command : Set key function.
- Iris Close command : Cancel function.
Note
■
Installation Procedures
Item
Initial value
BAUD RATE
Camera ID
2400
1
REMOTE
VIDEO OUT
DC
VIDEO
POWER
SET
F.G
AC24V/DC12V
D/N
IN G
M/D
OUT
UTP
OUT
RS485
AC24V/DC12V
Summary of Contents for DN83TSPX
Page 21: ... MENU ...