66
Parameter
Para. No.
(Hex)
Parameter value & option
Factory
default
Factory
default
Supp.
1: Enable
Set Length(s) for Code
39
0x12 (L1)
0x13 (L2)
0x00~0x99
0x00~0x99
(L1>L2 is not supported)
0x02
0x37
0x01
0x63
Yes
Code 39 Check Digit
Verification
0x30
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Transmit Code 39 Check
Digit
0x2B
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Code 39 Full ASCII
Conversion
0x11
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Code 93
Code 93 Read
0x09
0: Disable
1: Enable
0 (Disable)
1 (Enable)
Yes
Set Length(s) for Code
93
0x1A(L1)
0x1B(L2)
0x00~0x63
0x00~0x63
(L1>L2 is not supported)
0x04
0x37
0x01
0x63
Yes
Code 11
Code 11 Read
0x0A
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Set Lengths for Code 11
0x1C(L1)
0x1D(L2)
0x00~0x63
0x00~0x63
(L1>L2 is not supported)
0x04
0x37
0x04
0x63
Yes
Code 11 Check Digit
Verification
0x34
0: Disable
1: One check digit
2: Two check digit
0 (Disable)
1 (One check
digit)
Yes
Transmit Code 11 Check
Digit(s)
0x2F
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Interleaved 2 of 5
Interleaved 2 of 5 Read
0x06
0: Disable
1: Enable
1 (Enable)
Same as left
Yes
Set Length(s) for I 2 of 5
0x16 (L1)
0x17 (L2)
0x00~0x63
0x00~0x63
(L1>L2 is not supported)
0x0E
0x0E
0x06
0x63
Yes
I 2 of 5 Check Digit
Verification
0x31
0: Disable
1: USS Check Digit
2: OPCC Check Digit
0 (Disable)
Same as left
Yes
Transmit I 2 of 5 Check
Digit
0x2C
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Convert I 2 of 5 to EAN
13
0x52
0: Disable
1: Enable
0 (Disable)
Same as left
No
Chinese 2 of 5 (China Post)
Chinese 2 of 5 Read
0xF0
0: Disable
0 (Disable)
1 (Enable)
Yes
Reserved
FS01 & MS3391-L