50
6-22 UK/Plessey
Read:
Format
Data digits (variable) 2 check digits (optional)
Check digit verification: The UK/Plessey has two optional check digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Parameter name
Para. code Para. option
Para. value
Parameter (Para. No.)
Para.
value
Read
0x09 0x61
Disable
Enable
00
01*
UK_Plessey
(0xF2 0x90)
00
01*
Check digit verification
0x09 0x62
Disable
Enable
00
01*
UK_PlesseyCheckDigitVerification
(0xF2 0x91)
00
01*
Check digit transmission
0x09 0x63
Disable
Enable
00*
01
UK_PlesseyTransmitCheckDigit
(0xF2 0x92)
00*
01
Max. code length
0x09 0x64
00-99
00-99
99*
Min. code length
0x09 0x65
00-99
00-99
01*
Set Lengths for UK_Plessey
L1: (0xF2 0x93)
L2: (0xF2 0x94)
Note1
00*
00*
Code ID setting
0x09 0x66
00-FF
16
(ASCII)
00-FF
16
<U>*
UK_Plessey_CodeIDSetting
(0xF2 0x95)
<U>*
Insert group selection
0x09 0x67
00-44
00-44
00*
UK_Plessey_InsertGroupSelection
(0xF2 0x96)
00-44
00*
Reserved
0x09 0x68
-
-
Reserved
FS01 & MS3391-L