![Generalscan FS01&MS3391-L Configration User Manual Download Page 29](http://html1.mh-extra.com/html/generalscan/fs01andms3391-l/fs01andms3391-l_configration-user-manual_2210867029.webp)
42
Parameter name
Para. code Para. option
Para. value
Parameter (Para. No.)
Para.
value
Read
0x07 0x6D
Disable
Enable
00
01*
Codabar (0x07)
00*
01
Check digit verification
0x07 0x6E
Disable
Enable
00*
01
CodeBar_CheckDigit
Verification (0xF2 0x68)
00*
01
Check digit transmission
0x07 0x6F
Disable
Enable
00*
01
CodeBar_Transmit
CheckDigit (0xF2 0x69)
00*
01
Max. code length
0x07 0x70
00-99
00-99
99*
Min. code length
0x07 0x71
00-99
00-99
04*
Set Lengths for Codabar
L1:0x18
L2:0x19
Note1
05*
55*
Code ID setting
0x07 0x72
00-FF
16
(ASCII)
00-FF
16
<N>*
CodeBar_CodeIDSetting
(0xF2 0x6A)
<C> *
Insert group selection
0x07 0x73
00-44
00-44
00*
CodeBar_InsertGroup
Selection (0xF2 0x6B)
00*
Start/End type
0x07 0x74
ABCD/ABCD
abcd/abcd
ABCD/TN*E
abcd/tn*e
00*
01
02
03
CodeBar_StartEndTyp
(0xF2 0x6C)
00*
01
02
03
Start/End transmission
0x07 0x75
Disable
Enable
00*
01
NOTIS Editing (0x37)
Note2
01
00*
Start/End character equality
0x07 0x76
Disable
Enable
00*
01
CodeBar_StartEnd
CharacterEquality (0xF2 0x6D)
00*
01
Reserved
FS01 & MS3391-L