INTRODUCTION:

Thank you for purchasing this Infrared Thermometer. This is a non-contact infrared temperature measuring instrument.
Features include a 4 digits backlit LCD, scan/hold/auto function and auto power off (6 seconds). To measure a temperature,
point the unit at the desired object, pull the measuring trigger and hold till the end of the shot. Make sure the target area is
larger than the unit’s spot size.

IRT650

USER’S MANUAL

12 to 1 Wide-range Infrared Thermometer

IRT650 Manual-FINAL-050608:Layout 1  5/6/08  9:13 AM  Page 1

Summary of Contents for IRT650

Page 1: ...t LCD scan hold auto function and auto power off 6 seconds To measure a temperature point the unit at the desired object pull the measuring trigger and hold till the end of the shot Make sure the targ...

Page 2: ...fore using the meter CE Certification This instrument conforms to the following standards EN61326 Electrical equipment for measurement control and laboratory use IEC61000 4 2 Electrostatic discharge i...

Page 3: ...d displays temperature in either F C The user has to replace the battery when the battery voltage drops below the voltage for reliable operation and at the same time the low battery symbol will appear...

Page 4: ...by the target have fast response and are commonly used to measure moving and intermittent targets targets in a vacuum and targets that inaccessible due to hostile environments geometry limitations or...

Page 5: ...e technologie de semi conducteurs R paration et entretien des automobiles S curit et traitement de l alimentation Audits nerg tiques du chauffage de la climatisation et de la ventilation D tection de...

Page 6: ...en dedans de 25 4 F 32 20 C 3 F 2 C en dedans de 4 212 F 20 100 C 2 en dedans de 212 999 F 100 535 C Thermopile 5 14 m Reproductibilit 2 F 1 C R solution 0 1 F 0 1 C Temps de r ponse 500 ms Temp ratur...

Page 7: ...t une missivit de 0 8 absorbera 80 et refl tera 20 de l nergie incidente L missivit est d finie comme le ratio de l nergie irradi e par un objet une temp rature donn e comparativement l nergie irradi...

Page 8: ...guridad y procesamiento de alimentos Auditor as energ ticas en calefacci n ventilaci n y aire acondicionado HVAC Diagn stico de problemas el ctricos Prueba de terminales en circuitos Experimentos cien...

Page 9: ...u rea a medir 12 1 Rango de temperatura 25 a 999 F 32 a 535 C Precisi n a temperatura ambiental de 25 C 77 F 5 F 3 C de 25 a 4 F 32 a 20 C 3 F 2 C de 4 a 212 F 20 a 100 C 2 de 212 a 999 F 100 a 535 C...