Page 28
Unscrew two diametrically-opposite M16 x 80 head fixing screws (1 and 2, fig. 96) and replace them with
two service pin-screws (part #F27540200)(1, fig. 97), and then proceed to remove the remaining screws.
Remove the spacer for pump casing liner from the liner units (1, fig. 99).
Separate the head and the spacer from the pump casing liners (1 fig. 98).
GENERAL PUMP
A member of the Interpump Group
SMH SERIES
Ref 300894 Rev. B