Page 21
After finishing this operation, verify that the connecting rods have axial clearance in both
direction.
Insert the plunger guide seal rings in their casing by means of special tool part #F27605300. Position the
component on the rod (1, fig. 70a) and strike on the tool until the seal ring is fully inserted in the housing
(1, fig. 70b).
Insert the o-ring on the rear cover (1, fig. 71 and assemble the cover on the casing with the aid of (6)
M10x30 screws (1, fig. 72).
GENERAL PUMP
A member of the Interpump Group
SMH SERIES
Ref 300894 Rev. B