Fasten the ring gear stop (1, fig. 77) using (2) M10x25 screws. Calibrate the screws with a torque wrench
as indicated in Section 3, “Screw Tightening Calibration” (1, fig 78).
Apply the two Ø 10x24 pins on the reduction gear box (1, fig. 79) and insert the o-ring (1, fig. 80).
Complete assembly of the pinion on the reduction gear cover, proceeding as follows:
Pre-assemble the inner bearing ring 40x90x23 on the pinion (1, fig. 81) positioning it to end stroke.