Page 36
GENERAL PUMP
A member of the Interpump Group
SMH SERIES
fig. 126
fig. 127
fig. 128
fig. 129
Reassemble the seals support unit as shown in Fig. 128 and 129 replacing components pos. 1, 2, 3.
fig. 130
Assemble the L.P. and H.P. seals support units. – liner manually screwing the screws M8x100 as indicated
in Fig. 131. Then proceed with calibration using a torque wrench as indicated in Section 3 “Screw Tightening
Calibration”.
Ref 300894 Rev. B
05-22