GENERAL

®

 INTERNATIONAL WARRANTY

All component parts of General

®

 International and Excalibur by General International

®

 products 

are carefully inspected during all stages of production and each unit is thoroughly inspected upon 

completion of assembly.
 

Limited Lifetime Warranty

Because of our commitment to quality and customer satisfaction, General

®

 International agrees to 

repair or replace any part or component which upon examination, proves to be defective in either 

workmanship or material to the original purchaser for the life of the tool. However, the Limited Lifetime 

Warranty does not cover any product used for professional or commercial production purposes nor 

for industrial or educational applications. Such cases are covered by our Standard 2-year Limited 

Warranty only. The Limited Lifetime Warranty is also subject to the “Conditions and Exceptions” as listed 

below.

Standard 2-Year Limited Warranty

All products not covered by our lifetime warranty including products used in commercial, industrial 

and educational applications are warranted for a period of 2 years (24 months) from the date of 

purchase. General® International agrees to repair or replace any part or component which upon 

examination, proves to be defective in either workmanship or material to the original purchaser during 

this 2-year warranty period, subject to the “conditions and exceptions” as listed below.

To file a Claim

To file a claim under our Standard 2-year Limited Warranty or under our Limited Lifetime Warranty, 

all defective parts, components or machinery must be returned freight or postage prepaid to  

General® International, or to a nearby distributor, repair center or other location designated by 

General® International. For further details call our service department at 1-888-949-1161 or your local 

distributor for assistance when filing your claim.
 

Along with the return of the product being claimed for warranty, a copy of the original proof of purchase 

and a “letter of claim” must be included (a warranty claim form can also be used and can be obtained, 

upon request, from General

®

 International or an authorized distributor) clearly stating the model and 

serial number of the unit (if applicable) and including an explanation of the complaint or presumed 

defect in material or workmanship.

CONDITIONS AND EXCEPTIONS:

This coverage is extended to the original purchaser only. Prior warranty registration is not required but 

documented proof of purchase i.e. a copy of original sales invoice or receipt showing the date and 

location of the purchase as well as the purchase price paid, must be provided at the time of claim. 
Warranty does not include failures, breakage or defects deemed after inspection by  

General

®

 International to have been directly or indirectly caused by or resulting from; improper use, 

or lack of or improper maintenance, misuse or abuse, negligence, accidents, damage in handling or 

transport, or normal wear and tear of any generally considered consumable parts or components.

 

Repairs made without the written consent of General® International will void all warranty.

Summary of Contents for 10-055

Page 1: ...balanced impeller for smooth operation and minimal noise Reusable clear plastic collector bag Washable extra fine 5 micron filter bag Quick release bags clamps with metal straps Hole in base allows fl...

Page 2: ...from knowledgeable and qualified sources that it is safe to do so Once you ve read through these instructions keep this manual handy for future reference DISCLAIMER The information and specifications...

Page 3: ...rd 2 year Limited Warranty or under our Limited Lifetime Warranty all defective parts components or machinery must be returned freight or postage prepaid to General International or to a nearby distri...

Page 4: ...ller separator assembly 11 Installing the hose 11 Installing the filter bag 12 Installing the collector bag 13 Basic adjustments and controls 13 Connecting to a power source 13 On Off power switch 13...

Page 5: ...model or cartridges on CF model on a regular basis and replace as needed 11 Do not handle the electrical plug with wet hands 12 Do not use this unit outdoors or near wet surfaces 13 Always turn on the...

Page 6: ...eding CIRCUIT CAPACITY Make sure that the wires in your circuit are capable of handling the amperage draw from your machine as well as any other machines that could be operating on the same circuit If...

Page 7: ...AIN PARTS AND COMPONENTS A SWIVEL CASTER 4 B FLOOR SWEEP OPENING C BASE D DUST HOSE E IMPELLER SEPARATOR ASSEMBLY F SAFETY SWITCH G MOTOR H 5 MICRON FILTER BAG I QUICK RELEASE BAG CLAMP J COLLECTOR BA...

Page 8: ...B VERTICAL SUPPORT PANEL 2 C CROSS PANEL 1 D BAG HANGER 1 E BASE 1 F DUST HOSE 1 G FILTER BAG 1 H HOSE FITTING 1 I COLLECTOR BAG 1 J HOSE CLAMP 2 K BAG CLAMP 2 L CARRIAGE BOLT M8 X 12 4 M CARRIAGE BO...

Page 9: ...ver possible See the accompanying examples of non recommended and recommended installations Wherever possible avoid running hoses and ducting along the floor Keep hoses and ducting safely mounted alon...

Page 10: ...wn D E BEFORE ASSEMBLING MAKE SURE THAT THE SWITCH IS IN THE OFF POSITION AND THAT THE POWER CORD IS UNPLUGGED DO NOT PLUG IN OR TURN ON THE MACHINE UNTIL YOU HAVE COMPLETED THE ASSEMBLY AND INSTALLAT...

Page 11: ...ANUAL INSTALLING THE IMPELLER SEPARATOR ASSEMBLY 1 Install the separator on the frame 2 Align the mounting holes D with the correspond ing holes on the two sides of frame 3 Insert a carriage bolt E in...

Page 12: ...driver Repeat steps 1 to 2 with the other hose clamp then connect to the dust producing ma chine 12 INSTALLING THE HOSE CONTINUED INSTALLING THE FILTER BAG 1 Fit the bag hanger support into the holes...

Page 13: ...SK OF SHOCK OR FIRE DO NOT OPERATE THE UNIT WITH A DAMAGED POWER CORD OR PLUG RE PLACE DAMAGED CORD OR PLUG IMMEDIATELY TO AVOID UNEXPECTED OR UNINTENTIONAL START UP MAKE SURE THE POWER SWITCH IS IN T...

Page 14: ...NVIRONMENT IS TAKEN INTO CONSIDERATION MAINTENANCE MAKE SURE THE MACHINE HAS BEEN TURNED OFF AND UNPLUGGED FROM THE POWER SOURCE BEFORE PERFORM ING ANY MAINTENANCE OR ADJUSTMENTS PERIODIC MAINTENANCE...

Page 15: ...kbench and slowly passing the vacuum nozzle over the entire surface area 2 Reinstall the bag and reattach the clamp Note Filter bags can also be machine washed gentle cycle only in cold or warm water...

Page 16: ...16 DIAGRAM 10 055 1 7 2 2 3 4 29 5 6 8 13 9 10 11 12 14 21 16 17 18 19 20 22 30 31 33 34 26 25 24 15 23 27 32 28 36 35 8...

Page 17: ...10055 19 RIGHT SIDE PANEL 1 10055 20 IMPELLER 1 10055 21 HEX HEAD BOLT M8 X 12 4 10055 22 LOCK WASHER 4 10055 23 LARGE WASHER 1 10055 24 LOWER IMPELLER COVER 1 10055 25 CAP SCREW M6 X 1 1 10055 26 UP...

Page 18: ...Follow us 8360 Champ d Eau Montreal Quebec Canada H1P 1Y3 Tel 514 326 1161 Fax 514 326 5565 Parts Service 514 326 5555 Order Desk orderdesk general ca www general ca...

Reviews: