2-14
Installation
GDC 048R154-000
The network port interface is an RJ48C jack located on the rear panel.
You must use either GDC cable P/N 022H024-XXX (RJ48C plug-to-
plug) or 022H021-XXX (RJ48C plug-to-terminal lugs) to connect the
T1 line to the DSU. The plug-to-plug cable is labeled NETWORK and
CSU to indicate where each end is used.
Pinouts for the network end of the network interface cables are listed
below:
For Canadian installations only, a special cable is required
for the network connection. Use GDC cable P/N 022H020
(RJ48C to DB15F) to connect the network port to the T1
line.
Function
Direction
027H242-X04
022H024-XXX
Pin No.
022H025-XXX
022H021-XXX
Wire color
Receive Data (Ring)
To DSU
1
ORN/WHT
Receive Data (Tip)
To DSU
2
WHT/ORN
Send Data (Ring)
From DSU
4
BLU/WHT
Send Data (Tip)
From DSU
5
WHT/BLU
Shield (Frame Gnd.)
n/a
7
DRAIN
Note: The remaining leads are not used.
If you connect two DSUs back-to-back (a direct cable
connection), automatic Line Build-Out must not be enabled
for both. It may be enabled in one of the units, if so desired.
NOTE