12
Owner’s Manual for Portable Generator
Starting Pull Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Turn main breaker switch Off (A). See
4. Turn fuel valve On (B). See
.
.
Figure 3-2.Main Breaker Switch and
Fuel On/Off Valve
5. See
. Switch engine control lever
to Run (B).
.
Figure 3-3.Engine Control Lever
6. See
. Press control panel engine
Run/Stop switch to Run (C).
7. Squeeze primer bulb 5-10 times until firm.
The fuel filter should show fuel level at
least half full.
8. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Flip red
decompression lever on top of engine. Pull
rapidly up and away.
– Repeat this procedure until the engine
starts. If the engine does not start
within 5 pulls, confirm steps 1-6 and
perform step 7 again.
.
Figure 3-4.Engine Run/Stop Switch
1. Allow engine to run for at least 10 sec-
onds, then turn main breaker On (A). See
or
2. Select voltage rating with voltage selector
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. These outlets are pro-
tected against overload with push-to-reset
type circuit breakers. If amperage rating of
any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
carefully.
Starting Electric Start Engines
1. Turn main breaker switch to Off (A). See
or
2. Unplug all electrical loads from the unit's
receptacles before starting engine.
3. Place generator on a level surface.
4. Turn fuel valve On (A). See
5. See
. Switch engine control lever
to Run (B).
6. Squeeze primer bulb 5-10 times until firm.
The fuel filter should show fuel level at
least half full.
7. Press and hold the Engine Start switch (C)
until engine starts. See
Release Engine Start switch if engine
does not start within 5 seconds. If engine
does not start within 5 seconds, review
start-up procedure again before attempt-
ing start. If problems persist, refer to
.
8. Turn Main Breaker to On.
9. Select voltage rating with Voltage Selector
(D).
(000183)
WARNING
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
000708
B
A
000712
B
000714
D
C
A
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
Summary of Contents for XD5000E
Page 21: ...Owner s Manual for Portable Generator 19 Notes ...
Page 22: ...20 Owner s Manual for Portable Generator ...
Page 23: ......
Page 46: ...Manual del propietario del generador portátil 20 Notas ...
Page 47: ...Manual del propietario para generador portátil 21 Notas ...
Page 48: ...Manual del propietario para generador portátil 22 Notas ...
Page 49: ......
Page 72: ...Manuel de l utilisateur de la génératrice portable 20 Remarques ...
Page 73: ...Manuel de l utilisateur de la génératrice portable 21 Remarques ...
Page 74: ...22 Manuel de l utilisateur de la génératrice portable Remarques ...
Page 75: ......