Generac Power Systems RTSJ200A3 Owner'S Manual Download Page 2

Safety Rules .................................................Inside Front Cover
General Information ................................................................. 2

1.1 Introduction 

................................................................................ 2

1.2 Equipment 

Description 

................................................................ 2

 

1.2.1  Transfer Switch Mechanism .............................................. 2

 

1.2.2  Utility Service Disconnect Circuit Breaker .......................... 2

 

1.2.3  Load Shed Controller ........................................................ 3

1.3  Transfer Switch Data Decal ......................................................... 3
1.4  Transfer Switch Enclosure ........................................................... 3
1.5  Safe Use Of Transfer Switch........................................................ 4

Installation ............................................................................... 4

2.1  Introduction to Installation ........................................................... 4
2.2 Unpacking 

.................................................................................. 4

2.3 Mounting 

.................................................................................... 4

2.4  Connecting Power Source and Load Lines .................................. 4
2.5 Neutral 

Connections 

.................................................................... 5

2.6  Connecting Control Wires ........................................................... 5

Operation ................................................................................. 5

3.1  Functional Tests & Adjustments .................................................. 5
3.2 Manual 

Operation 

........................................................................ 5

 

3.2.1  ATS Manual Operation ...................................................... 5

 

3.2.2  LSS Manual Operation ...................................................... 6

 

3.2.3  Close to Utility Source Side ............................................... 6

 

3.2.4  Close to Generator Source Side ........................................ 6

 

3.2.5  Return to Utility Source Side ............................................. 6

3.3 Voltage 

Checks 

........................................................................... 7

3.4  Generator Tests Under Load ........................................................ 8
 

3.4.1  ATS & Critical Loads ......................................................... 8

 

3.4.2  Auto Operation and Load Shed Functional Test .................. 8

Notes ....................................................................................... 9
Installation Diagram .............................................................. 12
Interconnection Diagram ....................................................... 13

SAFETY RULES

 

 SAVE THESE INSTRUCTIONS - This manual 

contains important instructions that should 

be followed during installation and mainte-

nance of the generator and batteries.

 

 SAVE THESE INSTRUCTIONS!  Read the fol-

lowing information carefully before attempt-

ing to install, operate or service this equip-

ment. Also read the instructions and infor-

mation on tags, decals, and labels that may 

be affixed to the transfer switch. Replace any 

decal or label that is no longer legible.

 

 DANGER!  Connection of a generator to an 

electrical system normally supplied by an 

electric utility shall be by means of suitable 

transfer equipment so as to isolate the elec-

tric system from utility distribution system 

when the generator is operating (Article 701 

Legally Required Standby Systems or Article 

702 Optional Standby Systems, as appli-

cable). Failure to isolate electric system by 

these means may result in damage to gen-

erator and may result in injury or death to 

utility workers due to backfeed of electrical 

energy.

The manufacturer cannot anticipate every possible circumstance 

that might involve a hazard. The warnings in this manual, and on 

tags and decals affixed to the unit are, therefore, not all-inclusive. If 

using a procedure, work method or operating technique the manu-

facturer does not specifically recommend, ensure that it is safe for 

others. Also make sure the procedure, work method or operating 

technique chosen does not render the transfer switch unsafe.

Table of Contents

WARNING!

California Proposition 65

Engine exhaust and some of its constituents are known to the state of California to cause cancer, 

birth defects, and other reproductive harm.

WARNING!

California Proposition 65

This product contains or emits chemicals known to the state of California to cause cancer,

birth defects, and other reproductive harm.

Summary of Contents for RTSJ200A3

Page 1: ...This manual should remain with the unit Owner s Manual LTS Load Shed Switch...

Page 2: ...infor mation on tags decals and labels that may be affixed to the transfer switch Replace any decal or label that is no longer legible DANGER Connection of a generator to an electrical system normall...

Page 3: ...hazardous and possibly LETHAL electric shock DO NOT WORK ON THE TRANSFER SWITCH UNTIL ALL POWER VOLTAGE SUPPLIES TO THE SWITCH HAVE BEEN POSITIVELY TURNED OFF Competent qualified personnel should inst...

Page 4: ...will operate and disconnect the non essential loads which results in a reduction in the load on the generator The third function is a 16 circuit load center to connect the criti cal loads to These lo...

Page 5: ...switches 1 4 For one shot operation mode set DIP switch 5 to ON Reconnection of the non essential loads will occur one time after the time set on DIP switches 1 4 If DIP switch 5 is OFF the LSC will a...

Page 6: ...stalling Do not drop the switch Protect the switch against impact at all times and against construction grit and metal chips Never install a transfer switch that has been damaged This transfer switch...

Page 7: ...rals are to be connected on the busbars mounted on the load center next to the branch circuit breakers 2 6 CONNECTING CONTROL WIRES Control system interconnections consist of N1 N2 and T1 and leads 0...

Page 8: ...L position no further action is required If the handle is DOWN proceed with Step 1 Step 1 With the handle inserted into the moveable contact carrier arm move handle UP Be sure to hold on to the handle...

Page 9: ...NOW BEING DELIVERED TO TRANSFER SWITCH TERMINALS CONTACT WITH LIVE TERMINALS RESULTS IN EXTREMELY DANGEROUS AND POSSIBLY FATAL ELECTRICAL SHOCK 7 With an accurate AC voltmeter and frequency meter chec...

Page 10: ...ual Operation Handle and operating lever of transfer switch should be in UP position 10 Turn on the UTILITY power supply to transfer switch using the UTILITY SERVICE DISCONNECT circuit breaker The uti...

Page 11: ...9 Notes...

Page 12: ...10 Notes...

Page 13: ...11 Notes...

Page 14: ...12 Installation Diagram 200 Amp Enclosure Drawing 0G8775 B...

Page 15: ...8 9 B 2 1 3 9 8 7 B D1 A 6 3 4 5 2 1 7 6 3 2 1 4 5 1 2 2 1 3 1 2 3 4 5 6 J4 RL2 D2 1 2 2 1 3 TO LOADS NON ESSENTIAL TOP TERMINALS TO GROUNDING ELECTRODE 194 OPTIONAL ALARM CONTACT CUSTOMER SUPPLIED N...

Page 16: ...Part No 0H8807 Revision E 08 01 13 Printed in U S A...

Reviews: