Generac Power Systems PWRmanager Owner'S Manual Download Page 8

4

Owner’s Manual for Generac PWRmanager 12 Relay Load Controller

General Information

LED Status 

A

Status LED

Off

No power is available to the unit.

Red

Relay or unit is not operating normally. See 

Troubleshooting

 for 

more information.

Flashing Orange

Mode Selector Knob is not in normal position.

Blue

Unit is powered by the PWRcell system and no issues are 

detected.

Green

Unit is powered by the grid and no issues are detected.

B

 Relay LEDs

 Off

Relay is open.

Green

Relay is closed (load is enabled).

Red

Relay is not operating normally and remained in its last state 

(closed or open). See 

Troubleshooting

 for more information.

C

Relay Pairing 

LEDs

Off

Relays not paired.

Green

Relays are paired as 240 V circuit.

Red

Relays are paired, but at least one relay is not operating normally. 

See 

Troubleshooting

 for more information.

D

WiFi / Ethernet 

Status LED 

Green

Connected to Generac server.

Blue

Unit is either connected to the Internet using local WiFi or Ethernet 

connection, but it is not connected to the Generac server.

Flashing Blue

Connecting to local router via WiFi.

Red

Unable to connect to local router or Internet.

Flashing Green

Access Point (AP) mode broadcasting.

G

Grid State LED 

Green 

Grid power is available. Unit is powered by grid.

Blue

Grid power is not available. Unit is powered by PWRcell system.

Orange

Grid status is unknown.

Summary of Contents for PWRmanager

Page 1: ...fe This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at https pwrfl...

Page 2: ...label on this page See Serial Number Location When contacting an Independent Authorized Service Dealer IASD or Generac Customer Service always supply the complete model number and serial number of the...

Page 3: ...er 5 Circuit Groups 5 System Status and Settings 5 Navigation Bar 6 Controlling Loads in PWRview 6 Connecting to PWRmanager 7 Configuring PWRmanager 7 Configure Each Circuit 7 Add or Delete a Circuit...

Page 4: ...iv Installation Manual for Generac PWRmanager 12 Relay Load Controller This page intentionally left blank...

Page 5: ...it is safe for others and does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the unit DANGER WARNING CAUTION and NOTE blocks are used to alert personne...

Page 6: ...or serious injury 000209b WARNING Loss of life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury...

Page 7: ...es a richly integrated load management functionality when used with the PWRcell system Whole Home Backup With whole home backup during an outage the main breaker panel will be disconnected from the ut...

Page 8: ...losed or open See Troubleshooting for more information C Relay Pairing LEDs Off Relays not paired Green Relays are paired as 240 V circuit Red Relays are paired but at least one relay is not operating...

Page 9: ...g installation will appear in groups based on how they are currently controlled Manual Group See Figure 3 2 Circuits configured as manual on or off appear at the top of the list below the power source...

Page 10: ...It will show the current configuration for the circuit Tap one of the unselected radio buttons to change it The request will be executed and the panel will close Figure 3 6 Controlling Loads in PWRvi...

Page 11: ...1 Open the mobile device s WiFi configuration tab find the PWRmanager xxxxx WiFi AP network and connect to it 2 Open a browser on the device and point it at the IP address http 10 10 10 10 to open th...

Page 12: ...l last long enough during an extended outage This is the same as selecting Automatic Lock out in the PWRview app and will be modified by changes from the app Figure 3 10 Configuring Lockout Minimum Of...

Page 13: ...ons for circuit connections Read below for important points to consider when select ing circuits Loads can be wired through PWRmanager for load management or can be wired directly without passing thro...

Page 14: ...igured to run if they do not overload the inverter If the total load exceeds the power capacity of the inverter these will be shed in priority order to ensure the inverter continues to run Loads to co...

Page 15: ...R Outdoor Mounting Description Value Dimensions excluding flange Width 14 in x Height 9 in x Depth 5 in 35 56 cm x 22 86 cm x 12 7 cm Weight 14 3 lb 6 5 kg Wire Sizes 14 through 6 AWG Description Valu...

Page 16: ...Specifications 12 Owner s Manual for Generac PWRmanager 12 Relay Load Controller This page intentionally left blank...

Page 17: ...the installer Pressing the reset button for 10 seconds will reset the unit to out of the box conditions NOTE This will require that all WiFi information be entered again and will cause all relay and l...

Page 18: ...rload on the inverter from the unmanaged loads Turn off breakers on some unman aged loads as needed for inverter to continue to supply power All relays are on The web interface and app cannot change a...

Page 19: ...or Generac PWRmanager 12 Relay Load Controller 15 Dimensions and Drawings Section 6 Dimensions and Drawings Enclosure Base 150 5 9 400 15 7 78 3 1 288 11 3 45 1 8 18 7 41 1 6 38 1 5 DIMENSIONS ARE IN...

Page 20: ...16 Owner s Manual for Generac PWRmanager 12 Relay Load Controller Dimensions and Drawings This page intentionally left blank...

Page 21: ...Owner s Manual for Generac PWRmanager 12 Relay Load Controller 17 Dimensions and Drawings This page intentionally left blank...

Page 22: ...18 Owner s Manual for Generac PWRmanager 12 Relay Load Controller Dimensions and Drawings This page intentionally left blank...

Page 23: ......

Page 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W2929...

Reviews: