GEM-P816 Installation Instructions
L
NAPCO Security Systems
WI994C 3/04
!
Page 36
JP1: Cut to enable Keypad Tamper.
JP3: Note different zone terminal wiring required as shown in wiring diagram.
W1 & W3: Cut both to disable touch pad backlighting.
W2: Cut to disable LCD backlighting.
Keypad Jumpers (GEM-RP2ASe2)
Refer to label LA1390 on the circuit board fishpaper for jumper locations and a summary of settings. See Section 3: Configuring the
GEM-RP2ASe2 Keypad for jumper selection.
Keypad Features
The following programmed system features will activate only if they have also been enabled at the keypad.
!
Ambush
!
Easy Arming
!
Access Control
!
Keypad (Police) Panic
!
Keypad Auxiliary Panic
!
Keypad Fire Panic
Keypad: GEM-K Series Keypads
When “Enable GEM-K Series Keypads” are enabled, a Gem-RP1CAe2 keypad will display GEM-K Series Keypad features: It will
display “ARMED AWAY”, “ARMED STAY”, and “ARMED NIGHT” instead of “ARMED” “STAY MODE INTERIOR BYPASS” modes.
Keypad Panic
See Panic Zone
Keypad Sounder on Alarm
If a programmed zone goes into alarm, the keypad sounder will activate and will remain activated until the
C
button is pressed or
the system is disarmed.
Keypad Tamper
See Tamper
Keypad Zone Directory
* GEM-RP1CAe2 firmware version 5 or greater required
The GEM-RP1CAe2 will support the display of the Keypad Zone Directory. Press
R
until “DISPLAY ZN DIRECTORY Y/N” is
displayed and press [NEXT/YES]. Scroll through the zone directory by pressing [NEXT/YES] / [PRIOR/NO].
Keyswitch Arming; Maintained-Key Input Arming
The area will arm/disarm when the programmed zone is momentarily shorted (momentary keyswitch). To supervise the keyswitch,
program the zone for Day Zone on Open. Keyswitch Arming will be reported as User 36. Keyswitch must be provided with EOL
resistor. Maintained-key input arming will arm when shorted and disarm when opened.
Line-Reversal Module, M278
The Line-Reversal Module allows the panel to be monitored by a central station through leased lines. On alarm, the module reverses
normal line-voltage polarity. For details, refer to the instructions furnished with the module.
Loop Response (750mS required for UL installations)
Loop response is the amount of time in milliseconds (mS) that a normally-closed circuit must remain open, or a normally-open circuit
must remain closed, to trigger an alarm. The slower the loop response, the more immune the system will be to intermittents
(“swingers”). Loop response times for Zones 1 through 8 are programmed into the control panel; Zones 9-16 with “Zone Doubling”
enabled have loop responses the same as their respective 1-8 zones; those for Zones 9 through 32 loop responses are selected in the
respective keypad configuration mode or expansion zone module jumper. (Refer to keypad instructions and EZM Installation
Instructions.)
Selectable loop-response times for Zones 1–8 are:
750mS (.75 sec.): The slowest loop-response time, recommended for use with magnetic contacts, window foil, etc. Unless
programmed otherwise, loop-response time will be 750mS for all zones.
50mS (.05 sec.): Used for momentary Panic Buttons and area-protection devices, such as photoelectric eyes, passive infrared sensors,
floor mats, etc.
Low Battery; Wireless Low Battery; Keyfob Low Battery
A low-battery system trouble will annunciate at the keypad when the battery terminal voltage drops below normal. This condition may
signal a local sounding device, report to a central station (program Panel Low Bat Report Code), or both. If a battery is installed and
low terminal voltage is detected, a restore will not occur until the battery is recharged to its specified level and passes a dynamic test.
The dynamic test may be initiated manually by pressing the
C
button, or it will be initiated automatically, every four hours, by the
panel. In wireless installations, when displaying RF transmitter status, a “LoBatt” indication denotes a low-battery condition at the
transmitter.
Memory Failure
A User or Dealer Memory error will cause the sounder to pulse, the “
SYS/TRBL
” reminder to flash, and the display to read “
SYSTEM