![Gemini GEM-P816 Installation Instructions Manual Download Page 35](http://html.mh-extra.com/html/gemini/gem-p816/gem-p816_installation-instructions-manual_2207250035.webp)
L
NAPCO Security Systems
X
GEM-P816 Installation Instructions
WI994C 3/04
!
Page 33
Disable Wait-for-Silence (Pager Format)
Causes data transmission to start immediately after the pager telephone number.
Disable Zone Fault Scrolling/Disable Auto Status
Non 24-Hour Zones that are open (or shorted) normally display “
ZONE FAULTS
” (while disarmed) followed by the zone number(s) and
description(s). In high-security applications, program Disable Auto Status. Unsecured zones will then be indicated by a “
ZONE FAULTED”
display without zone numbers displayed. Status may be displayed manually using the DISPLAY STATUS function.
Double Reporting
See Report Telco 3
“
E” Lugs (E5, E15, E19)
(Not for UL installations)
E5 -
Lug E5 is used for Line Seizure. It is normally at 12V and when the telephone line is seized it goes to approximately 1V DC.
E15 -
Lug E15 is used for Armed Status, either Armed Stay or Armed Away (Address 1061). When the system is armed it goes to
approximately 1V DC. For multiple area systems: If only 1 area, Lug E15 goes active low when area 1 is armed; if two areas,
both area 1 and area 2 have to be armed for Lug B15 to go active low.
E19 -
Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad sounder and bell outputs
so that the Veri-phone can listen to activity at the residence. See Veri-Phone (WI783): Silence All Outputs During Audio Session.
Use Napco Part No. WL1 for field wiring.
Easy Exit
(Not Evaluated by UL)
While armed in the Interior Mode, Easy Exit can be initiated by pressing
D
or
U
. Easy Exit restarts the Exit delay, allowing a User to
exit an armed premises without disarming and rearming the system. Disable
D
or
U
buttons as Easy Exit.
Easy Programming of Auto download ID #‘s and PC Preset Callback #
(GEM-RP1CAe2/GEM-K1CA only)
It is now possible to set the PC Preset Auto download ID # and PC Preset Callback phone number from the GEM-RP1CAe2/GEM-
K1CA Easy Program Mode.
1. Enter Easy Program Mode and press PRIOR/NO until Central Phone # is displayed.
2. Program an “F” followed by the Auto Download ID # (2 digits) and then the Callback Telco # (up to 13 digits).
3. Press
U
to save.
4. Exit Program Mode ([RESET] [RESET]).
5. Enter Function Mode
6. Go to Function “ACTIVATE DOWNLOAD Y/N” and press NEXT/YES.
7. The panel will automatically call the PCPreset computer and download the program on the specified Auto DL line #.
Note:
After the auto download of the control panel program, the system must be fully tested.
--See following example:
Enable Alarm Output on Telco Fail only when Area(s) Armed (Alarm Output Only when Armed)
Allow Telephone Line Fault test to produce an Alarm Output only when armed.
Note:
requires “System Features: Alarm Output”, “Telco
Fail” and version 9 or later panel.
Enable CP-01 Limits
(SIA CP-01 Requirement: 4.2.5.1)
When address 1062 bit 3 is enabled, three time limits are enabled as per the SIA CP-01 standards: (1) Exit Delay Time: If an attempt
is made to change the Exit Delay time to less than 45 seconds the time will be entered as 60 seconds. The maximum programmable
time is 255 seconds; (2) Entry Delay: If an attempt is made to change the Entry Delay time to less than 30 seconds the time will be
entered as 30 seconds. The maximum programmable time is 255 seconds; and (3) Abort Delay: If an attempt is made to change the
Abort Delay to less than 15 seconds or more than 45 seconds the time will be entered as 30 seconds.
NOTE:
In accordance with UL standards, the aggregate of the Entry Delay time and Abort Delay time "window" will not be programmed to
exceed one minute.
Note:
When Address 1062 bit 3 "Enable CP-01 Limits" is enabled, the Exit Delay keypad sounder (including the
Exit Urgency sound during the final 10 seconds of the Exit Delay) is enabled.
Note:
If "Enable CP-01 Limits" is enabled in EZ Pro-
gramming, any Zone in a Group
will only activate an alarm and send a report ONCE
. After the Zone has reported, it will remain in the
Group and may still initiate the Zone ANDing sequence.
Enable Telephone Line Fault Test
Enable Line Fault Test will cause the panel to monitor the phone line. A failure will display as “
SYSTEM TROUBLE/E-08 SERVICE
” for Telco
Line Fail. Program this system trouble to activate the Burglary Output.
Glossar
y
Example: Program an Auto Download ID # of 07 and a PC Preset Callback # of 1-516-842-9400
•
Go to Central Phone # input screen and press: [*] [5] [0] [7] [1] [5] [1] [6] [8] [4] [2] [9] [4] [0] [0] [ON/OFF]
‘F’
Auto DL ID#
Callback Phone #
Save