E-Payment
MagIC
3
X-series - MAINTENANCE MANUAL
Chapter 2 :
TROUBLESHOOTING
Ref: 22000-00-MAN-I-09004
June 2009
Ch.2 - 33/37
Copyright Gemalto – 2008
No disclosure to a third party without prior written consent of Gemalto
3. SECURITY ALERT – How to interprete SP Status information
If the security has been tampered, a “SECURITY ALERT” message will be
displayed for few seconds at boot time.
And the “Key Icon” is blinking or stays permanently light, depending on the
current security status.
¾
If the key icon is blinking, it indicates that Terminal has its tamper status
triggered.
¾
If the key icon is enabled and not blinking, it indicates that at least one
switch or mesh is currently opened.
!!
Below content gives you some detailed information about Security Alert.
This can be usefull when you did not success by following procedure
described in §2.14. Remember, always starting by procedure §2.14 to
analyse Security Alert before going in the below information.
!!
Since hardware design is specific to each product, below information
are only relevant to X_series.
Key Icon