Fault clearance
PH300
Faults
The following lists possible faults during operation and their clearance.
The causes of these errors must be eliminated, before further procedures
are carried out.
Always check the following points first when there are faults in the fresh
powder supply:
–
Is mains voltage present?
–
Is compressed air present (min. 4 bar)?
Fault
Cause
Corrective action
Too little conveying
power
Fluidizing in the fresh
powder hopper not
switched on
Switch on fluidization
Too little fluidizing air
Adjust the fluidizing
air correctly
Powder pump
defective
See operating
manual of the
powder pump
The powder is not
fluidized
Compressed air not
present
Connect the
equipment to the
compressed air
Fluidizing air is set
too low
Adjust the fluidizing
air correctly
Powder discharges
from the fresh
powder hopper
Too little air pressure
at the Airmover
Set the Airmover air
correctly
Venting hose
clogged
Heavy sintering in
the Airmover
Conveying runs
continuously
Control incorrectly
set
Set the control
correctly