Rev. 00 01/22
PH300
Product description
•
11
Compressed air indicators
Fig. 3
DR1
Powder hopper fluidizing air
DR2
Compressed air input
Feed Control Hood
The fresh powder hopper has a powder outlet in the plate with a Dense
Phase Conveyor. If the powder hopper is switched off directly after
conveying, the still fluidized powder flows into the opening into the Dense
Phase Conveyor. At the next 'restart' this can lead to clogging, so that the
conveyor hose must be emptied first.
This feed control hood is inserted into the outlet opening. A ring slot
around the outlet opening is created by the hood, so that powder can only
flow slightly. The ring slot setting is, however, very much dependent on
the flow characteristics of the powder and must, therefore, be set
individually.
Because the Feed Control Hood is only a push fit, it can be removed for
setting or cleaning.
Fig. 4