OptiStar CG08(-C)
Initial start-up
•
31
Operation
NOTE:
During the initial commissioning of the device, it is recommended
that the functional check be performed without powder!
Select predefined operating mode (Preset mode)
1. Turn on the gun control unit with the
ON
key
2. Press the corresponding application key
the arrow above the pressed key is switched on
The pre-defined application modes have preset values for
high voltage and spray current:
Application mode
Preset µA
Preset kV
(flat parts)
100 100
(complex parts)
22 100
(overcoated)
10 100
3. The air values for total air, powder output and electrode
rinsing air can be individually defined and are saved in the
programs.
Starting the user-defined operating mode
(Program mode)
1. Turn on the gun control unit with the
ON
key
2. Press
program key
3. Select desired program (001-250)
4. Change coating parameters as required
NOTE:
Programs 001-250 are preset at the factory but can be modified at
any time, after which they are automatically stored.
Program 250 active