V
02/18
OptiStar CG08(-C)
Product description
•
19
Monitoring of wearing parts
Wearing parts have a limited service life. The OptiStar CG08(-C) gun
control unit offers functionality to monitor the service life of up to four
wearing parts using a reverse counter:
NOTE:
The order of wearing parts to be monitored as well as the service
life can be set as needed by the operator.
Example table:
No.
Wearing part
1 Insert
sleeve
2
Powder hose
3 Electrode
holder
4 Pulverizing
element
To better explain this function, a few terms relevant to this process must
first be explained:
Service life
Operating time after which wearing parts should
be replaced (defined by the operator).
Minus days
Number of hours past the selected service life
that the wearing part has continued to be used.
Operating life
Effective time during which the wearing part was
in operation = service life plus minus days, if any
Remaining
service life
displayed value (where not in the minus range)
-
The service life monitoring can be activated/deactivated for
each wearing part (see also "Initial start-up - Monitoring of
wearing parts")
-
By default all monitoring is deactivated and must be activated
by the operator
-
Query the remaining service life
-
Reset the operating time
-
Unit used for display of service life / operating time: 1 day
(x.x), range: 0.1 – 500 days