V
02/18
18
•
Product description
OptiStar CG08(-C)
Precise Control of spraying Current (PCC Mode)
For coating components with both complex and simple geometries, a
spraying current of below 10 µA can be selected to prevent unintended
overcoating on the simpler surfaces.
This is especially important in
combination with high loading powders (such as metallic). The controller
automatically switches into "PCC mode". This allows for very fast yet
highly precise control. The high voltage and spray current values and
their symbols are depicted in red:
Rinsing mode
The PowerClean mode is used to blow powder accumulations and
moisture out of the powder hose, injector, and gun using compressed air.
NOTE:
The rinsing mode can only be activated from standby mode, namely
by pressing the corresponding keys on the gun control unit or also
by an optional bus connection such as CAN bus.
The rinsing mode is signalized by a circling LCD segment on the display:
The actual rinsing procedure is started and stopped by the
superordinated control unit.
Once the rinsing mode is quit, the unit automatically returns to the last
program.