Rev. 00 08/17
MultiStar CG10
Operation
37
Selecting the preset coating programs (Easy
Mode only)
1.
Turn on the gun control unit with the
ON
key
2.
Press the corresponding application key.
The arrow above the desired button lights up.
The pre-defined application modes have preset values for high
voltage and spray current:
Application mode
Preset µA
Preset kV
flat parts
100
100
complicated parts
22
100
overcoat
10
100
3.
The air values for total air, powder output and electrode rinsing air
can be individually defined and are saved in the programs.
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
In Advanced Mode (P01=1), separate setpoints can be used for
the powder output volume, total air and electrode rinsing air for
each gun.
– The values displayed correspond to the guns which were
selected with the relevant button on the additional panel.
As a factory default value, a powder rate of 60% and a total air
volume of 4 Nm³/h are recommended.
– If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the
T3/T4
keys
–
Adjust the total air volume according to the corresponding coating
requests