No.
Description
Values
Display
P05
CAN Baud rate
0: 20 kbit/s
1: 50 kbit/s
2: 100 kbit/s
3:
125 kbit/s
4: 250 kbit/s
5: 500 kbit/s
6: 800 kbit/s
7: 1 Mbit/s
2 0
5 0
1 0 0
1 2 5
2 5 0
5 0 0
8 0 0
1 0 0 0
P06
CAN Node ID
1
-127
P07
Air volume
setting
0:
Standard (PA / GL)
1: Food (FL / ZL)
Std
Food
P10
Log level
0, 1,
2
, 3, 4, 5
LoG
Default values are marked by
bold
print.
7.
Press
key to quit the system parameter mode.
The display switches to the standard level
System parameter P00
fig. 13: System parameter P00
This parameter determines whether all connected guns are activated
simultaneously or individually.
–
The system parameter P00 is set to
0
when device is starting.
–
If the parameter is set to
1
, each individual gun can be controlled
externally via digital inputs. If the signal is not on, the gun cannot be
activated (triggered).