12.4.5 ProcessData Input Descriptor
The
ProcessData Input Descriptor
parameter describes the data format of the process data. Thus the master receives inform-
ation about the process data without IODD.
In-
dex
Sub
-
In-
dex
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x0E
0
0
RO
3 byte
ProcessData Input
Descriptor
ArrayT
0x00
0x03
0x01
Description of parameter values
Index name
Parameter
Values
Description
ProcessData Input
Descriptor
0x00
Bit offset
0x03
Type length
0x01
Data type -> BoolT
12.4.6 ProcessData Output Descriptor
The
ProcessData Output Descriptor
parameter describes the data format of the process data. Thus the master receives in-
formation about the process data without IODD.
In-
dex
Sub
-
In-
dex
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x0F
0
0
RO
3 byte
ProcessData
Output Descriptor
ArrayT
0x00
0x04
0x01
Description of parameter values
Index name
Parameter
Values
Description
ProcessData Output
Descriptor
0x00
Bit offset
0x04
Type length
0x01
Data type -> BoolT
12.4.7 Vendor name
The manufacturer name can be read out in ASCII format with the
Vendor name
parameter.
In-
dex
Sub
-
In-
dex
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x10
0
0
RO
5 bytes
Vendor name
StringT
"GEMUE"
12.4.8 Product name
The device name can be read out in ASCII format with the
Product name
parameter.
In-
dex
Sub
-
In-
dex
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x12
0
0
RO
18 byte
Product name
StringT
"eSyStep Positioner"
GEMÜ R563
www.gemu-group.com
29 / 53