12.4.32 Force settings
In-
dex
Sub-
In-
dex
Off-
set
Access
Rights
Length
Parameter
Type
Default
Values
0xC0
1
R/W
10 bits
Force Valve
uint:16
1000
0 to 1000
(0.0 to 100%)
2
R/W
10 bits
Force Init
uint:16
550
0 to 1000
(0.0 to 100%)
Description of parameter values
Parameter
Values
Description
Force Valve
0 to 1000
(0.0 to 100%)
Set the force of the valve.
Force Init
0 to 1000
(0.0 to 100%)
Set the force during initialization.
Force settings
Actuator size
Setting parameter
Force in Newton
AS 0
0 (0%)
0
500 (50%)
270
1000 (100%)
540
www.gemu-group.com
52 / 64
GEMÜ 543
Positioner (Code S0)
12 Specific data IO-Link (pin 6)