Index
Sub-
Index
Access
rights
Parameter
Function
Factory
settings
Setting options
2
R/W
Type digital input/output
Configure type of di-
gital inputs/outputs
0
0 → Push-Pull
1 → NPN
2 → PNP
0x4D
0
R/W
Function digital output
Configure digital out-
put
1
0 → Output Open
1 → Output Close
2 → Output Error
3 → Output Error &
Warning
0x4E
1
R/W
Logic digital
input 1
Configure logical di-
gital input 1
0
0 → Active high
1 → Active low
2
R/W
Logic digital
input 2
Configure logical di-
gital input 2
0
0 → Active high
1 → Active low
3
R/W
Logic digital input/out-
put
Configure logical di-
gital input/output
0
0 → Active high
1 → Active low
4
R/W
Logic digital
output
Configure logical di-
gital output
0
0 → Active high
1 → Active low
0x4F
1
R / W
Error Action
Set safety position
Code S0 / S5: 2
Code S6: 1
0 → Hold
1 → Open
2 → Close
2
R / W
Error Time
Determine time from
error detection to error
message
1 (0,1s)
1 … 1000
(0,1s … 100s)
0x50
1
R/W
Inversion of LED Colours
Activate / deactivate
inversion of LEDs
0
0 → Standard
1 → Inversed
2
R/W
On Site Initialization
Activate / deactivate
on site initialization
0
0 → Enabled
1 → Disabled
3
R/W
Initialization Mode
Activate / deactivate
set initialization mode
0
0 → Positioner
1 → OPEN/CLOSE
4
R/W
IO-Link Process Data
Activate/deactivate
use of IO-Link process
data
0
0 → Disabled
1 → Enabled
0x51
1
R/W
Actuator Position Feed-
back OPEN request
Request valve position
OPEN
900
(90.0%)
30 to 970
(3.0 to 97.0%)
2
R/W
Actuator Position Feed-
back CLOSED request
Request valve position
CLOSED
100
(10.0%)
30 to 970
(3.0 to 97.0%)
0x53
1
RO
Open
Analogue value valve
position OPEN
0 to 4095
2
RO
Closed
Analogue value valve
position CLOSED
0 to 4095
0x55
1
RO
Max.
OPEN end position
0 to 4095
2
RO
Min.
CLOSED end position
0 to 4095
0x56
1
R/W
User
Customer switching
cycles (resettable)
0
0 to 16,777,215
2
RO
Total
Total of switching
cycles (not resettable)
0
0 to 16,777,215
0x60
1
RO
Potentiometer
Analogue value poten-
tiometer
0 to 4095
2
RO
Supply Voltage
Analogue value supply
voltage
0 to 4095
3
RO
Temperature
Analogue value tem-
perature sensor
0 to 4095
4
RO
Set value input
Analogue value signal
input
0 to 4095
GEMÜ 543
Positioner (Code S0)
www.gemu-group.com
37 / 64
12 Specific data IO-Link (pin 6)