7
www.geiger.de
EN
EN
9. Conductor assignment for SMI drives for mains voltage
1 2
3 4
l+
l+: Control wire +
l-: Control wire -
PE: Protective earth conductor
L: Live
N: Neutral wire
Names
PE
l-
L N
l+
Ab
Au
f
PE
l-
L N
Drive
1 2
3 4
Push button operation
Drive
l+
PE
l-
L N
1 2
3 4
Telegram operation
Drive
Changing the operating mode from telegram operation to pushbutton operation is done by
switching the power supply off and on.
Connector on drive cables
The STAS4 connector from Hirschmann
is recommended.
Cable connections and connector
assignment for the STAS4/STAK4
connection system with
cables
having black, grey, brown, blue
and yellow-green wires
STAS 4 / STAK 4 Wire colour
Name
1
2
3
4
5 (PE)
black
grey
brown
blue
green-yellow
I+
I-
L
N
PE
Cable connections and connector
assignment for the STAS4/STAK4
connector system with
cables
having 2 black wires
STAS 4 / STAK 4 Wire colour
Name
1
2
3
4
5 (PE)
black 1
black 2
brown
blue
green-yellow
I+
I-
L
N
PE
Definition of the black wires:
black 1: between blue and green-yellow
black 2: between brown and green-yellow
Note on laying SMI wires in
custom cables
The I+ and I- SMI wires can be laid in the motor connec
-
tion line of the SMI drive (as above) or in their own cable.
It is not permitted to lay SMI wires together with wires
carrying other signals in one cable.
If SMI drives wired in parallel are supplied with electrical
power from different phases, the SMI I+ and I- wires
must be laid in a separate cable.