17
80290C_MHW_2400_0908_ENG
PV :
Displays the process variable, identifies menus,
identificative, parameter values and error codes
F:
Displayes the index value for the variable shown on the PV display,
units of measurement defined in configuration
Raises/Lowers the value of the parameter displayed in SV until the max/min value
is reached.
When kept pushed: progressively increases the raise/lower speed of the value
displayed.
Lets you navigate the menus and parameters.
Confirms the value of the current (or modified by ) parameter and
selects the next parameter.
Buttons (for configuration, see parameter
BVT1, BVT2, BVT3
on
KRD
menu)
Standard configuration:
activation maximum peak input IN1
check calibration strain-gauge input IN1
disabled (no function)
The functions are active only when the display shows the process variable at
level 1
Confirms the value of the current (or modified by ) parameter and selects
the preceding parameter.
alarm state indicators:
ON
OFF
Function indicators: for configuration, see parameter
LeD.1
,
LeD.2
,
LeD.3
,
LeD.4
on
KRD
menu.
Standard configuration:
L1
= ON (displays max. peak IN1)
L2
= ON (automatic calibration control IN1)
L3
= ON (DI1 on) repeat DI1
OFF (DI1 off)
L4
= ON (DI2 on) repeat DI2
OFF (DI2 off)
3 • FUNCTIONS
This section describes the use and functions of the displays, lighted indicators and buttons making up the
instrument 2400 operator interface.
It therefore contains essential information for correct programming and configuration of the controllers.
Operator interface
ID
Symbol
Function
+
AL1 AL2 ................... AL10