page | 11
Operating the DisplayPort Detective Plus
Loading an EDID from a Bank
The
DisplayPort Detective Plus
provides the option of loading the EDID data, stored in a
EDID bank, to the local input (
DP In
).
1. Begin by powering-on the
DisplayPort Detective Plus
.
2.
Select the EDID from the EDID bank, using the piano DIP switches. Refer to the
chart, below. DIP switch 4 is not used when selecting an EDID bank.
Bank
DIP SW 1
DIP SW 2
DIP SW 3
DIP SW 4
0
OFF
OFF
OFF
Not used
1
ON
OFF
OFF
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
5
ON
OFF
ON
6
OFF
ON
ON
7
ON
ON
ON
3.
Set the
WR
(write) switch to the
“E”
position in order to allow the EDID to be written
to the local input.
4. Press the
Prog
button. The
Power
LED will slowly flash blue as the EDID is written
to the local input. Once completed, the
Power
LED will glow solid blue.
EDID Programming
NOTE:
Before an EDID can be loaded to the local input, the EDID
must be stored in an EDID bank. See
Recording an EDID to a EDID
Bank
for more information.
Slide switch to
the “
E”
position
DIP switches