![Gefen EXT-2DVI-DLKVM-CAT6 User Manual Download Page 17](http://html1.mh-extra.com/html/gefen/ext-2dvi-dlkvm-cat6/ext-2dvi-dlkvm-cat6_user-manual_2204934017.webp)
1 2 3 4 5 6 7 8
Gefen has specifically engineered products to work with the TIA/EIA-568-B
specification. Please follow the table below when field terminating cable for
use with Gefen products. Failure to do so may produce unexpected results and
reduced performance.
This product was designed for use with CAT-6a (augmented) cabling only. This
unit will either not perform to specification or refuse to operate completely if
cabling other than CAT-6a is used.
Each cable run must consist of a single undivided segment of CAT-6a cabling
from Sender to Receiver. Punch-down blocks or splices will not work.
Pin
Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
13