DIP SWITCH CONFIGURATION
DIP Switch Location
On the bottom of both the Sender unit and Receiver unit is a bank four (4) DIP
switches.
The DIP switches on the Sender unit allow the management of EDID, fiber optic
extenders, and HDCP.
Sender unit
DIP Switch 1 - EDID Management
• ON - Pass Through EDID
DDC and HPD are passed through. Both the connection status and the full
video capabilities of the monitor. All video features of the connected devices
are passed to the source device.
• OFF (default) - Local EDID
When Local EDID mode is used, the EDID will be assembled by copying all
video features of the connected output device.
The four DIP switches on the
bottom of the Sender unit.
NOTE:
The DIP switches on the Receiver unit do not provide any
function and are reserved for future expansion.