MANUAL BCSI-1 REV 1.8 EN.DOC
19.12.08
A.J.
- 78 -
Safety Instructions
General Safety Instructions
General Safety Instructions
General Safety Instructions
General Safety Instructions
The instructions stated in this chapter are to be followed accurately to ensure a safe and reliable operation.
The license and the special conditions included in it are to be observed.
Follow the national safety regulations and the accident prevention regulations.
The installation is only to be performed by specialists. These specialist must be familiar with the characteristics of
explosion-endangered facilities.
Incorrect or inadmissible application as well as non-observance of the instructions of this operating manual make
the guarantee void.
For BCSi-RF10/RF100 only: The BT-modul has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules and with RSS-210 of IndustryCanada as LMO. This device
contains transmitter with FCCID: RFR- C11G2, IC ID: 4957A-C11G2. The BT-modul is a qualified design
according to the Bluetooth Qualification Program Reference Document (PRD) V2.0. The Qualified Design ID
(QDID) is: B012419.
The products BCSi-C LP, BCSI-RF 10 and BCSi-RF 100 contain NiMH cells. Handle / recycle product regarding
local safety rules.
Only use this device for the approved purpose.
Conversions and modifications to the device are inadmissible.
The housing is only to be opened by the company Gecma Components GmbH.
The first two digits of the serial number located at the nameplate identify the year of manufacture
.
Assembly
Assembly
Assembly
Assembly
The national assembly and installation regulations are to be observed.
The generally accepted rules of engineering are to be observed.
The entire equipment is to be connected and operated correctly and properly according to the applicable
standards, guidelines and installation instructions.
Shielded cables are recommended for use in combination with this device.
Before putting the device into operation make sure that the device has been installed as prescribed and that the device and
its wiring are not damaged.
If the power supply of the device is not intrinsically safe, the license will become void and it must not be operated as an
intrinsically safe device. If the device was operated intrinsically safely with a low level of international protection (e.g. ib), it
must not be operated afterwards in applications for a higher level of international protection (e.g. ia).
Operation
Operation
Operation
Operation
The device is only to be operated in an undamaged and clean condition.
If the device has suffered any damages which might affect the international protection (e.g. cracks, holes or broken
components) it must be taken out of service immediately. The device can only be put into operation again after the
defect components have been exchanged.
When the device is damaged, do not touch it any longer! Risk of injury!
If the device is to be used in a dust atmosphere dust layers >5mm have to be removed.
In the event of non-observance & non-compliance the stipulated explosion protection cannot be guaranteed
and/or the guarantee will become void!
This laser component emits CDRH Class II/IEC Class I laser light. Do not stare into beam.
Modifications require the written approval by the company GeCma Components GmbH.