Setting economy duration*
The display will show Edxx, “xx” representing the duration in
hours of the economy mode� Use the arrow keys to adjust
the hour� Use the
Light
key to jump to the next parameter,
temperature unit�
24 = continuous economy
Setting temperature unit
Water temperature can be displayed in either Fahrenheit (°F)
or Celsius (°C)� The display will show °F or °C�
Use the arrow keys to change the setting�
Use the
Program
or
Light
key to save all the parameters�
Smart Winter Mode
Our Smart Winter Mode protects your system from the
cold by turning pumps on several times a day to prevent
water from freezing in pipes�
The “SWM” indicator lights up when freezing is
detected and flashes when the purge is active�
Water temperature regulation
Every 15 to 90 minutes the pump will run to ensure
accurate water temperature readings as well as avoid
heater activation in dry conditions� After verifying pump
activation and taking a water temperature reading if
required, the system automatically turns the heater on to
reach and maintain water temperature at Set Point�
Indicator flashes when taking water
temperature reading�
Cooldown
After heating the spa water to the desired Set Point, the
heater is turned off, but its associated pump (Pump 1
low-speed or CP) remains on for a predetermined period
of time to ensure adequate cooling of the heating element,
prolonging its useful life�
*
Note that the parameters for the economy mode settings are associated to specific low level configuration of the system that are not present in
all software revisions.