Setting economy duration*

The display will show Edxx, “xx” representing the duration in 
hours of the economy mode� Use the arrow keys to adjust 
the hour� Use the 

Light

 key to jump to the next parameter, 

temperature unit�

24 = continuous economy

Setting temperature unit

Water temperature can be displayed in either Fahrenheit (°F) 
or Celsius (°C)� The display will show °F or °C� 

Use the arrow keys to change the setting� 
Use the 

Program

 or 

Light

 key to save all the parameters�

Smart Winter Mode 

Our Smart Winter Mode protects your system from the 
cold by turning pumps on several times a day to prevent 
water from freezing in pipes�

   

   

The “SWM” indicator lights up when freezing is  

              detected and flashes when the purge is active�

Water temperature regulation

Every 15 to 90 minutes the pump will run to ensure 
accurate water temperature readings as well as avoid 
heater activation in dry conditions� After verifying pump 
activation and taking a water temperature reading if 
required, the system automatically turns the heater on to 
reach and maintain water temperature at Set Point�
 
         Indicator flashes when taking water 

            temperature reading�

Cooldown 

After heating the spa water to the desired Set Point, the 
heater is turned off, but its associated pump (Pump 1 
low-speed or CP) remains on for a predetermined period 
of time to ensure adequate cooling of the heating element, 
prolonging its useful life� 

Note that the parameters for the economy mode settings are associated to specific low level configuration of the system that are not  present in 

all software revisions.

Programming steps

Summary of Contents for in.k300

Page 1: ...ns Qu bec Qc G2E 5W6 Canada 1 800 78 GECKO www geckoalliance com Printed in Canada 9919 101218 D Rev 02 2018 Groupe Gecko Alliance Inc 2018 All trademarks or registered trademarks are the property of...

Page 2: ...Off Mode 7 Programming steps 8 Program menu 8 Setting the clock 8 Programming the filter purge cycles 8 Setting filter or purge cycle start time 9 Setting filter cycle duration 9 Setting filter or pu...

Page 3: ...ETAILS HAZARDOUS CONDITION A CONDITION THAT IS POTENTIALLY DAMAGING AND OR DANGEROUS TO THE OPERATOR OR SURROUNDINGS THIS INCLUDES BUT IS NOT LIMITED TO FIRE FLOODING OR OTHER WATER DAMAGE DIELECTRIC...

Page 4: ...nough to be seen in day simple enough to use in the middle of the night affordable yet solidly built Item in k300 Static LCD size as measured diagonally 1 5 Optional mounting with wing nuts and spacer...

Page 5: ...e installation surface and peel the adhesive gasket from the back of the keypad Insert keypad and align it correctly then ensure it is properly glued by gently pressing evenly on the entire surface Ga...

Page 6: ...5 Drilling template 36 58 mm 144 02 mm 131 32 mm R 6 35 mm R 6 35 mm...

Page 7: ...00 Main keypad in k300 in xe in xm 2 To connect the in k300 keypad simply insert its in link connector into the appropriate keypad connector of the pack enclosure as illustrated in ye in yt To connect...

Page 8: ...red temperature The set point icon will appear at the top of the screen After 3 seconds without any change to the set temperature value the keypad will resume the normal display Off Mode Pressing Pump...

Page 9: ...s to adjust the hour Press the Light key to jump to the next parameter the minutes Setting the minutes Use the arrow keys to adjust the minutes Press the Light key to jump to the next parameter the fi...

Page 10: ...quency FF 0 no filtration 24 continuous filtration It is not recommended to set this to 0 Setting economy mode This mode allows you to lower the temperature set point of the spa by 20 F 11 C during a...

Page 11: ...hes when the purge is active Water temperature regulation Every 15 to 90 minutes the pump will run to ensure accurate water temperature readings as well as avoid heater activation in dry conditions Af...

Page 12: ...in xm2 in therm incompatible SC ER Learning mode error F1 in xm2 Fuse 1 is blown F2 in xm2 Fuse 2 is blown F3 in xm2 Fuse 3 is blown Hr Danger Thermal fuse error UPL The spa pack does not have valid...

Page 13: ...tal Operating temperature 68 F 20 C to 149 F 65 C Storage temperature 22 F 30 C to 185 F 85 C Humidity Up to 70 condensing Water ingress protection IPX 5 Mechanical Weight 0 69 lb 313 g Dimensions W x...

Page 14: ...ns Qu bec Qc G2E 5W6 Canada 1 800 78 GECKO www geckoalliance com Printed in Canada 9919 101218 D Rev 02 2018 Groupe Gecko Alliance Inc 2018 All trademarks or registered trademarks are the property of...

Reviews: