GENERAL DESCRIPTION 
 

The gas detector system is compound of GAMMA 654-O/M or GAMMA

 

654-O/G central unit and GAMMA 

656C/M or GAMMA 656C/G remote gas

 

leak. 

The  detectors  GAMMA  654-O/M  and  GAMMA  654-O/G  are  central  units  of

 

methane  and  LPG  gas,  that 

warns with an  optical and acoustic signal, the

 

presence of gas in the environment. They are planed to be 

functioning as

 

central unit and as remote unit. GAMMA 656C/M and GAMMA 656C/G are

 

the remotes gas 

leak detector to be connected to central unit GAMMA 654-O/M or GAMMA 654-O/G. The detectors series 
GAMMA  are  calibrated  to

 

detect  gas  up  to  10%  of  the  L.E.L.  (Low  Explosion  Limit),  this  threshold  can

 

change in base of the environmental conditions but it will not gets over

 

during the first 4 years working, the 

15%  LEL,  after  that  period  the  instrument  have  to  be  put  out  of  order  or  re-send  to  Geca  S.r.l.  for  a 
complete

 

substitution  of  the  device.  With  that  aim,  for  this  purpose  on  the  cover  you

 

will  find  a  label  on 

which  have  to  be  indicated  the  maturity  of  correct  working

 

period  (4  years  from  installing  date);  this  label 

have to be compiled by who

 

makes the installation. 

 

СВЕТОВАЯ

 

И

 

АКУСТИЧЕСКАЯ

 

СИГНАЛИЗАЦИЯ

 

LUMINOUS AND ACOUSTIC SIGNALISATIONS 

 

Данные

 

газовые

 

детекторы

 

снабжены

 

тремя

 

световыми

 

сигнальными

 

индикаторами

находящимися

 

на

 

передней

 

панели

 
These gas detectors are provided, on the front panel, by three luminous signaiisations: 

 

 

ЗЕЛЕНЫЙ

 

ИНДИКАТОР

 (

ВКЛЮЧЕНО

): 

указывает

 

на

 

то

что

 

питание

 

на

 

прибор

 

подано

GREEN LED (ON): indicates that the instruments is powered 

 
 

ЖЕЛТЫЙ

 

ИНДИКАТОР

 (

НЕИСПРАВНОСТЬ

): 

указывает

 

на

 

то

что

 

датчик

 

газа

 

неисправен

YELLOW LED (FAULT): indicates that the gas sensor is

 

damaged 

КРАСНЫЙ

 

ИНДИКАТОР

 (

АВАРИЙНЫЙ

 

СИГНАЛ

): 

указывает

 

на

 

то

что

 

концентрация

 

газа

 

в

 

воздухе

 

превышает

 

аварийный

 

уровень

RED LED (ALARM): Indicates that the gas concentration 

measured in the air exceeds the alarm threshold 

 

В

 

случае

 

неисправности

 

датчика

 

устройство

 

указывает

 

на

 

неверную

 

работу

 – 

горит

 

желтый

 

светодиодный

 

индикатор

включается

 

прерывистый

 

звуковой

 

аварийный

 

сигнал

 

с

 2-

секундным

 

интервалом

.

 

В

 

случае

 

аварийного

 

сигнала

 

с

 

дистанционного

 

датчика

 

или

 

базового

 

устройства

 

загорается

 

красный

 

светодиодный

 

индикатор

 

и

спустя

 20 

секунд

зуммер

 

подает

 

звуковой

 

аварийный

 

сигнал

 

и

 

срабатывает

 

реле

In  case  of  damage,  gas  detectors  are  able  to  signals  the  malfunction,

 

illuminating in fixed way the yellow led and activating a sound alarm

 

with two 

seconds'  of  intermittence.  In  case  of  alarm  from  the  central

 

unit  or  from  an 

remote sensor illuminating the red led and after 20

 

seconds the buzzer emits a 

sound alarm and the relay activates.

 

Summary of Contents for 654-O/G

Page 1: ...supply Gas detected 654 O M 230 12 Methane 654 O G 230 12 LPG 656C M 230 12 Methane 656C G 230 12 LPG GAMMA 654 O M GAMMA 654 O G GAMMA 656C M 656C G GAMMA 654 O M GAMMA 654 O G GAMMA 656C M GAMMA 65...

Page 2: ...to be put out of order or re send to Geca S r l for a complete substitution of the device With that aim for this purpose on the cover you will find a label on which have to be indicated the maturity...

Page 3: ...n the heating phase During this time all the detection functions will be inhibited GAMMA 654 O M GAMMA 656C M 30 GAMMA654 O G GAMMA 656C G 30 1 4 METHANE Detector L P G Detector INSTALLATION Attention...

Page 4: ...g Directly over the sink or the gas device In little locals where can be utilised alcohol ammonia spray bottles of gas or other substances with flying solvents In low ventilated environments Near to w...

Page 5: ...M GAMMA 652C G GAMMA 652 O M GAMMA 652 O G 3 5 6 REMOTE CONNECTION The central unit has two clamps 5 6 active in closeness to be connected with an remote sensor GAMMA 656C M or with GAMMA 656C G or w...

Page 6: ...LVE 4 OPERATIONAL WITH NORMALLY CLOSED VALVE ELECTRICAL CONNECTION WITH MORE THEN ONE CENTRAL UNITS The following plans mentioned shows the connection in between two central units with an single elect...

Page 7: ...MA 656C G OPERATING CONTROLS After the installation it is possible to check the correct use of the instrument by pushing for at least 2 seconds the TEST button on the GAMMA 654 O M or GAMMA 654 O G bo...

Page 8: ...rms We recommend to ventilate the room where products like these can be used Note that the detector is not able to detect gas leaking outside the room where it is installed neither inside walls or und...

Page 9: ...not apparent and or cannot be corrected vacate the premises and immediately notify the gas emergency service 230 50 12 2 5 20 10 C 40 C 30 90 10 1 GAMMA 654 O 20 85 A 1 IP42 GAMMA 654 O TECHNICAL CHA...

Page 10: ...__________ TO COMPILE BY THE INSTALLER Installation date _____________________________________ Substitution date ____________________________________ Installation local _______________________________...

Page 11: ...chase date Any damages caused by tampering and incorrect use or installation will be not covered by warranty The warranty is valid only if is full compiled In case of defects covered by warranty the p...

Page 12: ...srl it 0134108 2 710 1509 GECAs r l GECA S r l reserves the right to make any aesthetic or functional modification to the without prior notice at any time WARRANTY CERTIFICATE TO COMPILE AND SEND IN C...

Reviews: