CHOKE LEVER
The choke lever is used to provide an enriched fuel
mixture when starting a cold engine. Slowly put the
choke lever to “OPEN” position after the engine is
started.
AC CIRCUIT BREAKER/OVERCURRENT
PROTECTOR
The overload current will automatically switch off
circuit breaker to avoid short circuiting of the load or
overload. If the indicator of AC Overcurrent Protector
is raised, the Overcurrent Protector is now in the
“OFF” position. Press the button of AC Overcurrent
Protector to the “ON” position again a few minute
later. If the circuit breaker is switched OFF
automatically, switch the circuit breaker ON again.
GROUND TERMINAL
This ground terminal is dedicated to reliably
grounding the whole generator.
OIL ALERT SYSTEM
The oil alert system is especially designed to
prevent engine damage caused by an insufficient
amount of oil in the crankcase. When the oil level
in the crankcase fall down below the safe limit, the
oil alert system will automatically shut down the
engine(though the generator switch still remain
in the ON position), so that the engine can’t be
damaged due to the insufficient amount of oil.
GENERATOR OPERATION
Generator operation environment:
· Temperature:-15°C - 40°C.
· Humidity: below 95%.
· Height above sea level: below 1,000m
(If the area is over 1,000m high, the power should
be lowered for operation).
CONNECTION TO THE HOUSEHOLD POWER
SUPPLY
When connecting the generator to a household power
supply, connection must be made by a qualified
electrician. After connecting, carefully check electric
connection for their safety and reliability, if not,
damage to the generator,burning and firing may be
caused.
GENERATOR GROUNDING
To prevent electrical shock or misuse from faulty
appliances, the generator should be grounded with
an insulated lead.
AC CURRENT
Before starting the generator,make sure that total
power of loads(total of resistive,capactive and
inductive loads)does not exceed rated power of the
generator.
NOTICE
Overload operation will greatly shorten generator
service life.
If the generator set is connected to multiple loads or
electric appliances,please first connect to one with
the highest starting power,then,the one with the
second highest starting power,and connect others
one by one,each with a lower starting power than
the preceding one, finally, connect the one with the
lowest starting power.