18
19
English
English
DC CURRENT
The DC terminals are used to provide power supply
for lower-power DC loads and charging other
batteries. The terminals are colored as such:red
to identify the positive (+) terminal and black to
identify the negative (-) terminal. Load connection
method: The load must be connected to DC terminals
with the proper polarity (load’s positive to positive of
DC terminal.
DC OVERCURRENT PROTECTOR
The overload current will automatically switch off
overcurrent protector to avoid short circuit of the
load or overload. If the indicator of overcurrent
protector is raised, the overcurrent protector is now
in the “OFF” position. Press the button of overcurrent
protector to the “ON” position again.
PRE-OPERATION CHECK
ENGINE OIL
Engine oil is a major factor affecting engine
performance and service life. Non-detergent and
2-stroke engine oils will damage the engine and are
not recommended.Check the oil level before each
use with the generator on a level surface with the
engine stopped.
Recommended engine oil:
Engine oil type
SAE 10W-30
Engine oil quality
API Service SF type, or higher
quality.
METHOD OF CHECKING ENGINE OIL LEVEL
Remove the oil filler cap and wipe the dipstick to
clean it. Check the oil level by inserting the dipstick
into the filler neck without screwing it in.
If the level is low, add the recommended engine oil
until level can reach the upper mark on the dipstick.
After adding, don’t forget to refit and screw the oil
dipstick tight.
FUEL
1. Check the fuel level gauge,
2. Replenish the tank if the fuel level is low. Do not
let oil level rise above the shoulder of the fuel
strainer.
3. Refit and screw the fuel tank cap tight after
refueling.
•
WARNING
Refuel in a well-ventilated area with the engine
stopped. Never smoke or allow flames or sparks
in the area where the engine is refueled or where
gasoline is stored.
• Do not overfill the fuel tank.
• Avoid repeated or prolonged contact with skin or
breathing in of fuel vapor.
• Keep children from contacting fuel.
• Never use the oil/gasoline mixture or gasoline
contained impurity.
BATTERY
NOTICE
Don’t connect the battery positive and negative
poles reversely(pay attention to leads mark), if not,
serious damage may be caused to the generator set
and battery.
• If improper operation, the battery may be
explosive and may potentially hurt persons nearby.
Keep the fire and inflammable materials far away
from the battery.
• The battery will release the explosive gas, please
keep the fire far away from it. Keep a good air
ventilation condition when battery is being charged
or used.
STARTING THE ENGINE
RECOIL STARTER
1. Remove all the loads from the output side.
2. Turn the fuel valve to the “ON” position.
3. Turn the AC circuit breaker to the“OFF” position.
4. Turn the choke lever to the“CLOSE” position.
NOTICE
Don’t close the choke when starting the engine in
warm state
5. Turn the generator switch to the “ON” position.
6. Pull the starter grip until a resistance is felt,then
pull it out briskly.
Summary of Contents for POWERMAN 8500 GR-ES
Page 1: ...POWERMAN 8500 GR ES ART NR 570752 MANUAL...
Page 13: ...13 Norsk...
Page 25: ...25 English...
Page 26: ...26 English E...