GeBe POWERMAN 2000i Manual Download Page 1

POWERMAN 2000i

ART.NR. 570814

MANUAL

Summary of Contents for POWERMAN 2000i

Page 1: ...POWERMAN 2000i ART NR 570814 MANUAL...

Page 2: ...n og varsel symboler p aggregatet ikke dekke alle farlige forhold Hvis vi ikke gir ekstra forsiktighetsregler for operasjonsprosedyrer metoder eller teknikker betjen generatoren p en slik m te at det...

Page 3: ...er jordet p en sikker m te Hvis generatoren skal kobles til str mnettet hjemme som en standby skal tilkoblingen utf res av en profesjonell elektriker N r lasten er koblet til generator m du sjekke n y...

Page 4: ...tf res f r du forlater enheten og etter at den er sl tt av En advarsel minner brukeren p at han skal overholde forskrifter for elektrisk sikkerhet som gjelder for stedet der aggregatet brukes En advar...

Page 5: ...lyse r dt dersom det tilkobles og brukes utstyr som krever mer str m enn aggregatet produserer om inverter overopphetes eller om spenningen ker For hindre skade p aggregatet og tilkoblet utstyr vil b...

Page 6: ...r for ESC m st i posisjon OFF n r det brukes utstyr som krever h y startstr m TANKLOKK 1 Skru av tanklokket ved dreie det mot urviserne 2 Tanklokket 2 er utrustet med vrider 1 for pne og lukke ventila...

Page 7: ...2 Skru ut skruene 1 ta av sidepanel 2 3 Skru ut oljep fyllingslokket 3 4 Fyll motorolje i henhold til spesifikasjonene Fyll til vre gjenge i p fyllingshullet Skru deretter tilbake oljep fyllingslokke...

Page 8: ...en hurtig til deg TIPS For hindre at aggregatet velter under oppstart hold et godt tak i b reh ndtaket n r du drar i startsnoren Slipp ikke startsnoren hurtig tilbake F r den forsiktig tilbake for unn...

Page 9: ...for batteriet Automatsikringen vil l se ut ved overbelastning av DC kursen dersom batteriet trekker for mye ladestr m eller om det er foretatt en feilkopling Dersom dette oppst r vent noen minutter f...

Page 10: ...belastning kan skade generatoren Ved tilkopling av sensitivt utstyr som PC TV lesebrett datamaskiner elektroniske m leinstrumenter eller elektroniske batteriladere s rg for holde avstand til str maggr...

Page 11: ...gj r og skift dersom n dvendig Bensinfilter Rengj r og skift dersom n dvendig Slange for veivhusventilasjon Kontroller slange for sprekkdannelser eller annen skade Skift ved behov Topplokk Fjern sotda...

Page 12: ...sert serviceverksted OLJESKIFT Motorens oljekvalitet er en avgj rende faktor for motorens ytelse og levetid Bruk kun anbefalt motorolje 3mguWSUa 1 Plasser str maggregatet p et horisontalt niv ved kont...

Page 13: ...e dersom de er skadet 5 Skift gnistfangere dersom de er skadet Bruk aldri str maggregatet p steder hvor det kan oppst brann uten at gnistfangere er montert som i skogsomr der Eventuelle gnister kan fo...

Page 14: ...ette kan ta opp til 20 minutter TIPS Gj r denne operasjonen uten at noe er tilkoblet aggregatet Hvor lang tid det vil ta f r motoren stopper avhenger av hvor mye bensin som er igjen p tanken etter t m...

Page 15: ...elastning 63 5 dB Lpa DC 12 V effekt 12 V 8 A Overbelastning DC Automatsikring AC Varsellampe MOTOR Motor modell Loncin LC148F Motor type Luftkj lt 1 sylindret 4 takts OHV bensinmotor Sylindervolum 79...

Page 16: ...ek over slukk ikke aggr lys Lonc OBS bryt begg 1 Pa ka 2 St g 3 Ti st 4 St I tilf tilko lyse seku tilleg begg over start ikke Ko ty Br pa Ti m Sk fje KOBLINGSSKJEMA Standardmodell 230V 50Hz Spesialmod...

Page 17: ...t aggregat m spesialkabelen fjernes Bruk av PM2000i som er parallellkoplet Ved benytte spesialkablene som medf lger aggregatene kan 2 stk PM2000i parallell koples for ke avgitt effekt F lg instruksjon...

Page 18: ...reason warnings in this manual and caution signs on the generator may not cover all hazardous circumstances If we do not give extra cautions for operating procedures methods or techniques operate the...

Page 19: ...realize safe grounding Use the ground wire with enough electric flux If the generator is to be connected to a home power supply as a standby connection shall be performed by a professional electrician...

Page 20: ...e and after switching it off A warning reminding the user that he shall conform to regulations of electrical safety applicable to the place where the generating sets are used A warning on the requirem...

Page 21: ...erload indicator light 1 comes on when an overload of a connected electrical device is detected the inverter control unit overheats or the AC output voltage rises Then the AC protector will trip stopp...

Page 22: ...e turned to OFF when using electric devices that require a large starting current such as a compressor of a submergible pump FUEL TANK CAP 1 Remove the fuel tank cap by turning it counterclockwise 2 T...

Page 23: ...ne This could result in overfilling and damage to the engine 1 Place the generator on a level surface 2 Remove the screws 2 and then remove the cover 3 3 Remove the oil filler cap 1 4 Fill with the sp...

Page 24: ...oad on the generator In ambient temperature below 0 C the engine will run at the rated 5000r min for 5 minutes to warm up the engine In ambient temperature below 5 C the engine will run at the rated r...

Page 25: ...n or other disturbances Charge the battery in the correct procedure by following instructions in the owner s manual for the battery The DC protector turns off automatically if current above the rated...

Page 26: ...hat electrical noise from the engine does not interfere with any other electrical devices located near the generator If the generator is to supply medical equipment advice should first be obtained by...

Page 27: ...tion Clean and replace if necessary Fuel filter Clean and replace if necessary Crankcase breather hose Check hose weather for cracks or damage Replace if necessary Cylinder head Decarbonizes cylinder...

Page 28: ...date and equipment to do so properly ENGINE OIL REPLACEMENT Avoid draining the engine oil immediately after stopping the engine The oil is hot and should be handled with care to avoid burns 1 Place t...

Page 29: ...fler When cleaning use the wire brush lightly to avoid damaging or scratching the muffler screen and spark arrester 4 Check the muffler screen and spark arrester replace if it damage 5 Install spark a...

Page 30: ...nning engine depends on the amount of the fuel left in the tank Fuel is highly flammable and poisonous Check SAFETY INFORMATION Immediately wipe off spilled fuel with a clean dry soft cloth since fuel...

Page 31: ...oise Level 3 4 load 63 5 dB Lpa DC Output 12 V 8 A Overload DC Automatsikring AC Varsellampe Engine Engine modell Loncin LC148F Engine type Luftkj lt 1 sylindret 4 takts OHV bensinmotor Displacement 7...

Page 32: ...z 230V Without Parallel Receptacle 50Hz 230V With Parallel Receptacle Para Befo gene cond exce equi in op on t norm ass requ red l over NOT ESC both 1 Co co 2 St in 3 Co 4 St In ca appl on T seco outl...

Page 33: ...cable must be done with the engines turned off Always remove cable if only using one generator How to use PM2000i in parallel operation By using the cable kit you can connect 2 pcs PM2000i in paralle...

Page 34: ...34...

Page 35: ...35...

Page 36: ...samsvar med f lgende direktiver og standarder Intygar att denna produkt verensst mmer med kraven i f ljande direktiv och standarder Product Inverter generator Str maggregat Elverk Model Gebe 570814 PM...

Reviews: