Main Board Terminal Strip
Caution:
Improper wiring may damage the
Zoneline electronics. Damage or erratic operation
may result. No common busing is permitted. A
separate wire pair must be run from each
separate controlling switch to each individual
Zoneline.
The terminal connections are located behind the
front case panel.
Insert the building hookup wires into the bottom of
the terminal and tighten screw securely to make
the desired connections.
Route any wires from the terminal connections
through the case loop.
Room Air Sensor
Motion Sensor
Door Sensor
Central Desk Control
Common–Ground
White–Heater
Yellow–Compressor
Black–Reversing Valve
Green–High Speed Fan
Green–Low Speed Fan
Red–24 V AC only
Common - Ground
Room Air Sensor
Motion Sensor
Door Sensor
Central Desk
Control
White - Heat Signal
Yellow - Cool Signal
Unused
Green - High Speed Fan
Green - Low Speed Fan
Red - 24 VAC Only
ON/OFF Switch
GEA01240
Terminal
Connections