Cool Mode Operation
Note:
•
Minimum compressor/fans off time is 3 m/- 10 seconds.
•
Reversing valve is energized at all times in cool mode. Reversing valve is not de-energized
when thermostat is satisfied.
•
Indoor and outdoor fans always operate at the same time in cool mode.
Currently Cooling
Indoor fan, outdoor
fan, compressor,
reversing valve
energized.
Thermostat
satisfied.
Indoor fan, outdoor
fan, compressor
off.
Compressor
energized.
Currently Off
Set thermostat to
cool. Adjust
thermostat to setting
below room
temperature.
Indoor fan, outdoor
fan, reversing
valve energized.
Thermostat not
satisfied.
Indoor fan, outdoor
fan energized.
3 SECOND
DELAY
3
SECOND
DELAY