D
GB
F
E
27
96156-03.2016-DGb
Οnderung
2.1
0
Datum
Name
Datum
Bearb.
Gepr.
Norm
1
20.02.2009
Kelich
28.05.2015
Urspr.
2
Ers. f.
3
Ers. d.
4
D/S
INT69 HG44/56
5
6
7
BOCK COMPRESSORS
8
=
+
9
Bl.
6.2
Bl.
6
2.2
Anschlußkasten Verdichter
BT1
BP1
P-Öl
MP10
QA1
L1
L2
L3
N
PE
FC1.1
I>
I>
I>
QA2
FC1.2
I>
I>
I>
PE
U1
V1
W1
EC1
M
3
˜
QA4
Y
W2
U2
V2
QA3
D
FC1.1
FC1.2
FC2
SF1
QA2
QA2
2.7
2.1.5
2.1.7
.5
13
14 2.5
QA4
BP2
P>
KF1
QA4
QA3
2.8
2.1.8
KF1
QA3
QA4
2.8
2.1.8
KF1
P
BP3
QA2
EB1
L1.1
L2.1
L3.1
L1.2
N
PE
BT2
Θ
BT3
T2
N
L
M
S
QA2
PE
BT2
Θ
X1 L1 L1 N N 43 43 11
12
14
L
S
M
X2 1 2 3 4 5 6
FC1.1/1.2 Motor protection switch
FC2
Control power circuit fuse
KF1
Delay relay for contactor changeover
QA1
Main switch
QA2
Mains contactor
QA3
Δ
-contactor
QA4
Y-contactor
SF1
Control voltage switch