Handling and assembly
Spreading nozzles assembly (optional)
2018-9015-005
09-2016
5.14
Spreading nozzles assembly (optional)
5.14.1 Nozzles without manual directional valve
Top nozzle assembly
1
2
3
4
6
5
● Place the O-ring (1) around the lid of the adapter (2);
● Place the adapter (2) on the anti-siphon end (3). Bolt the assembly using
provided hardware;
● Insert the seal (4) inside the spreading nozzle (5);
● Apply grade 2 PRECISION
TM
XL5 MOLY EP2 grease (or equivalent) on the
seal (4);
● Slide the spreading nozzle (5) over the adapter end (2) until it reaches the
welded ring on the adapter;
● Install a circle lock clamp (6) over the junction of the spreading nozzle and
of the adapter.