Handling and assembly
Nursing kit assembly (optional)
2018-9015-005
09-2016
5.9
Nursing kit assembly (optional)
Warning!
Beware of potential falls: always walk on the nonslip band installed on
the product.
Attention!
To lift the nursing kit assembly, use a lifting device with a minimum
lifting capacity of 1450 lbs [650 kg].
1
2
3
4
5
6
7
8
9
EL54 model shown
● Install the transfer pipe receptacle (1) on top of the spreader using four
locknuts, flat washers and a rubber gasket (2);
● Assemble the transfer pipe (3) using bolts, flat washers and locknuts.
Tighten all nuts;
● Apply grade 2 PRECISION
TM
XL5 MOLY EP2 grease (or equivalent) on the
pipe end (4) to facilitate the transfer pipe assembly (3);
● Lift the transfer pipe assembly (3) using an appropriate lifting device.
Position it over the pipe end (4). Slowly lower the transfer pipe assembly (3)
to lean over the pipe end (4) so that the pipe gear (5) fits into the motor
gear (6);
● Assemble two retaining brackets (7) on the vertical pipe using bolts and lock
washers;
● Connect the hydraulic hoses to the hydraulic motor (8) and to the hydraulic
cylinder (9).