2.
Turn the actuator base clockwise using the
flexible head spanner
.
!
Rotate the actuator base until the assembly spring can be removed.
Fig.59:
Unscrewing assembly spring
®
Assembly spring has been removed.
PA80 - PA255: dismantling the actuator
Carry out the following steps:
1.
Lift off the actuator base from the cylinder.
Fig.60:
Removing actuator base
2.
Use the
mounting tool for the spring package
to pull the spring package
upwards and out of the cylinder.
!
Pay attention to the installation direction of the spring assembly (NC / NO
direction of action) already when disassembling.
Maintenance
Disassembling and Assembling Actuator PA80 - PA255
430BAL011547EN_2
08.07.2019
57