Fig.47:
Water bath
6.
Remove the internal assembly from the
pressurizing tool
in reverse order.
®
This completes the leak test.
10.11
Disassembling and Assembling Actuator PA50/PA60
10.11.1 Disassembling Actuator PA50/PA60
Caution!
Danger of injury due to spring force being released
You may be injured if the spring tension is released in an uncontrolled
manner, causing actuator parts to be moved or thrown around rapidly.
► Load and unload the spring in a controlled and slow manner.
► Wear protective gloves for all work.
► Always exercise caution and prudence.
Tools required:
•
Hand-operated press
•
Seeger circlip pliers
•
Mounting tool bushing
•
Mounting tool for O-ring
Carry out the following steps:
1.
Press the base of the actuator downwards, using the
hand-operated press
with the
bushing
.
Maintenance
Disassembling and Assembling Actuator PA50/PA60
430BAL011547EN_2
50