10.6.2 Assembling the valve
Hint!
Pay attention to the following point when assembling the valve:
•
Thoroughly clean all parts and check for damage.
Tools required:
•
Hex socket key
Carry out the following steps:
1.
Install the valve in the reverse order of disassembly, see Section 10.6.1,
Page 38.
!
Note “Torques for clamps” table, see Section 10.6.3, Page 40
2.
Test the function of the valve after assembling.
!
Every possible position must be activated and held for 3-5 seconds to
assure proper assembly and sealing.
®
The valve has been assembled.
10.6.3 Torques for clamp
Clamp screw thread size
Recommended torque [Nm]
M6
10
M8
20
10.7
Disassembling and Assembling the Internal Assembly
10.7.1 Disassembling the internal assembly
Caution!
Danger of injury due to valve parts moved by compressed air!
You can sustain injuries to your fingers when you put your hand into the
valve while it is switching.
► Wear protective gloves for all work.
► Always exercise caution and prudence.
Requirement:
•
Internal assembly and actuator have been separated from the housing, see
chapter Section 10.6.1, Page 38.
Carry out the following steps:
1.
Bring drive in a horizontal position and then to “closed” position.
!
The T-slot in the piston rod must point upwards.
Maintenance
Disassembling and Assembling the Internal Assembly
430BAL011547EN_2
40